Table 11.
Algorithms applied to real signals. Average Accuracy, Correlation coefficient and associated parameters (Memory Based CUSUM Detector).
| Optimal value | MBCD-Acc. | MBCD-Ang. | MBCD-SUM. | MBCD-PROD. |
|---|---|---|---|---|
| Accuracy | 0.9576 ± 0.0080 | 0.9414 ± 0.0164 | 0.9414 ± 0.0165 | 0.9434 ± 0.0154 |
| Correlation coeff. | 0.9010 ± 0.0153 | 0.8588 ± 0.0465 | 0.8583 ± 0.0469 | 0.8635 ± 0.0429 |
| Window length | 12.6167 ± 4.1869 | 15.2500 ± 6.4345 | 15.0500 ± 6.8720 | 14.5167 ± 6.6832 |
| Threshold | 3.468e-6 ± 2.049e-6 | 0.3588 ± 0.1731 | 0.3551 ± 0.1746 | 0.4346 ± 0.1690 |