Hemodynamic values before and after fluid challenge in fluid responders and nonrespondersa

Nonresponders (n = 31) Responders (n = 34)

Parameters Before After P value Before After P value
Mean arterial pressure, mmHg 71 ± 8 76 ± 8 0.01 71 ± 9 77 ± 9 <0.01
Heart rate, beats/minute 105 ± 21 102 ± 21 0.12 103 ± 17 98 ± 18 0.04
Central venous pressure, mmHg 12 ± 4 14 ± 3 <0.01 9 ± 4 12 ± 4 0.01
Pulmonary artery occlusion pressure, mmHg 14 ± 3 17 ± 6 0.02 12 ± 3 14 ± 5 <0.01
Mixed venous oxygen saturation, % 67 ± 9 67 ± 9 0.97 67 ± 7 71 ± 6 <0.01
Cardiac index, L/minute/m2 3 ± 0.9 3.2 ± 0.6 0.23 2.9 ± 0.8 3.6 ± 0.9 <0.01

aData are presented as mean ± SD.