Skip to main content
. 2012 Jun 22;3(7):1701–1712. doi: 10.1364/BOE.3.001701

Fig. 3.

Fig. 3

Effects of background scattering properties on fit parameters. Filled circle represents the predicted fit parameters for an inclusion at the specified depth and thickness in (left) our phantom model (μa = 0.2 mm−1, μs = 4.0 mm−1, and g = 0.8) and (right) in our skin-like model (μa = 0.2 mm−1, μs = 45 mm−1 (100 micron thick epidermis) and μs = 30 mm−1 (dermis) and g = 0.8). The colored triangles represent fit results when the background scattering coefficient is increased by 10% (upward pointing triangles) or decreased by 10% (downward pointing triangles). While the absolute prediction for each location changes somewhat, the trends related to relative depth and thickness are retained.