Table 2.

Summary of RV ejection fractions from 6 active band models compared with their corresponding passive band models. Zero-stress end of systole band length for the passive band model was 4.18 cm. The zero-stress end of systole band length for the active band models with 10%, 15% and 20% active contraction were 3.76, 3.55, and 3.34 cm, respectively. Parameter for band material: c1=900 kPa, D1=0 kPa, D2=0.

Models Band Active Contraction (BAC) End of Systole RV Vol (ml) End of Dystole RV Vol (ml) EF(%)
Models with Patch and Scar
Base Model No Band 252.5 403.8 37.48%
PBM13 Passive 246.4 373.9 34.10%
ABM1 BAC=10% 246.1 393.3 37.43%
ABM2 BAC=15% 237.9 392.6 39.39%
ABM3 BAC=20% 234.1 389.6 39.92%
Models with Patch and Scar Replaced by Normal Tissue
PBM14 Passive 247.1 383.7 35.59%
ABM4 BAC=10% 246.7 408.1 39.54%
ABM5 BAC=15% 238.6 404.4 40.99%
ABM6 BAC=20% 234.7 402.1 41.63%