TABLE 1.

SEC-UV/MALS/RI analysis of Endo H-treated and untreated SOSIP.664GnTl−/−

UV extinction coefficient A2800.1%a Estimatedb (dn/dc)glycoprotein d Expected MMproteinc of monomer MMproteinfrom SEC-UV/MALS/RIe,f Calculated stoichiometry MMglycan from SEC-UV/MALS/RI MMglycoprotein from SEC-UV/MALS/RI Hydrodynamic radius, rHf
ml mg1cm1 ml/g g/mol g/mol nm
Untreated SOSIP.664GnTl−/− 1,649 0.168 74,332.6 220,600 2.97 173,500 394,200 12.3
Endo H-treated SOSIP.664GnTl−/− 1,649 0.179 74,332.6 223,500 3.01 36,500 260,000 9.9

a Extinction coefficient at 280 nm measured in water.

b Refractive index increment value.

c Molar mass.

d From the basic principles of molar mass determination by light scattering, it follows that any ± 1% error in the dn/dc value will propagate as a corresponding ± 1% error in the calculated molar mass (59).

e For SEC-UV/MALS/RI analysis of glycoproteins, a typical error is ± 10%. The source of uncertainty predominantly arises from the amount of sample analyzed and the stability of the system (59).

f Errors propagated in the various calculations performed by Astra V range between 0.2 and 50%.