Table 3.
CSLO Parameter Used: |
Rim Area |
Cup Volume |
Cup-Disc Ratio |
||||||
Coefficient |
SE |
P |
Coefficient |
SE |
P |
Coefficient |
SE |
P |
|
CSLO parameter | 0.010 | 0.026 | 0.066 | −0.129 | 0.061 | 0.036 | −0.262 | 0.103 | 0.011 |
MD at start of sequence | −0.073 | 0.006 | <0.001 | −0.081 | 0.006 | <0.001 | −0.111 | 0.008 | <0.001 |
PSD at start of sequence | −0.013 | 0.008 | 0.093 | −0.013 | 0.008 | 0.097 | −0.076 | 0.010 | <0.001 |
Age at start of sequence | −0.007 | 0.002 | 0.001 | −0.006 | 0.002 | 0.013 | −0.005 | 0.002 | 0.029 |
Maximum IOP in sequence | −0.013 | 0.004 | 0.001 | −0.013 | 0.004 | 0.001 | −0.016 | 0.004 | <0.001 |
Rate of change in visual acuity | −308 | 134 | 0.021 | −299 | 129 | 0.022 | −220 | 120 | 0.066 |
Each model uses one CSLO parameter (as indicated at the top of each column) together with other predictors to predict the rate of change of mean deviation (MD) over sequences of six tests, as described in the methods section. For each fixed effect included in the model, the fitted coefficient is shown together with its associated standard error (SE) and P value.