Table 4.

Comparison of the efficiency of the present method with other techniques

Dataset (# of cases) Reported prediction accuracy (%) Accuracy (%) using
Rp Dp
Jones (56) 68 82a 72a
Stawiski (54) 81
Stawiski enzyme data set (16) 50 92b 62b

aThe present method was applied to the combined Jones and Stawiski datasets as given in Table 2.

bBased on 13 cases (three could not be used as no surface patch showed up).