Skip to main content
. Author manuscript; available in PMC: 2013 Jul 21.
Published in final edited form as: Phys Med Biol. 2012 Jul 2;57(14):4683–4704. doi: 10.1088/0031-9155/57/14/4683

Table 5.

Impact of the technical improvements on syndesmophyte volume and height differences for the phantom.

n Mean +/- Std CV
mm3 % %
VOLUMES Initial algorithm 54 12.5 +/- 8.73 2.08 +/- 1.45 1.79
With subvoxel cutting only 54 6.25 +/- 4.61 1.15 +/- 0.85 1.01
With density and Laplacian only 54 12.5 +/- 7.10 2.34 +/- 1.31 1.90
With density and Laplacian and blur equalization only 54 12.3 +/- 6.98 2.29 +/- 1.28 1.86
Final algorithm 54 5.19 +/- 3.72 1.07 +/- 0.77 0.932
mm % %
HEIGHTS Initial algorithm 54 0.18 +/- 0.12 1.21 +/- 0.81 1.03
With subvoxel cutting only 54 0.17 +/- 0.12 1.12 +/- 0.80 0.972
With density and Laplacian only 54 0.19 +/- 0.14 1.28 +/- 0.97 1.14
With density and Laplacian and blur equalization only 54 0.19 +/- 0.15 1.26 +/- 0.98 1.13
Final algorithm 54 0.18 +/- 0.14 1.18 +/- 0.88 1.04