Skip to main content
. 2012 Mar 31;36(9):1947–1951. doi: 10.1007/s00264-012-1533-6

Table 1.

Initial tensile strength after different suture techniques for Achilles tendon repair

Type Sample size Strength (N) 95 % confidence interval (CI)
Lower Upper
Bunnell 37 217.2 214.3 220.1
Kessler 40 167.7 164.0 171.3
Krackow 67 172.7 171.0 174.4
Achillon 10 342.0 331.4 352.6
Ma-Griffith 13 149.5 145.3 153.8
Giftbox 13 168.0 160.1 175.9
Triple Bundle 8 453.0 445.8 460.2