Table 1.

Whole-slice averaged signals, noises, and SNRs of perfusion difference images at seven delays using different acquisition methods

Method Delay1 Delay 2 Delay 3 Delay 4 Delay 5 Delay 6 Delay 7
Hadamard Signal *20.29±5.18 22.00±2.26 21.67±2.39 14.22±1.54 6.99±1.00 5.47±1.24 4.82±0.98
Noise 3.25±0.19 3.36±0.25 3.43±0.36 3.57±0.42 3.51±0.31 3.38±0.34 3.31±0.31
SNR 6.22±1.46 6.58±0.83 6.41±1.19 4.02±0.61 2.00±0.31 1.64±0.41 1.46±0.24
Sequential Signal 18.57±5.77 22.98±2.30 23.17±2.24 16.06±2.59 7.72±1.11 5.95±2.94 2.57±2.21
Noise 6.76±0.65 6.70±0.59 6.88±0.73 6.63±0.34 6.69±0.52 6.87±0.61 6.44±0.40
SNR 2.78±0.97 3.47±0.56 3.38±0.20 2.43±0.40 1.16±0.20 0.86±0.38 0.40±0.33
*

Values are mean ± standard deviation across subjects.