Skip to main content
. 2012 Sep;19(9):1480–1486. doi: 10.1128/CVI.00234-12

Table 3.

Comparison of double-antigen sandwich ELISA with IIF and commercial indirect ELISA kit

Double-antigen sandwich ELISA resulta No. of serum samples
IIF
Commercial kitb
Positive Negative Total Positive Negative Total
Positive 251 7 258 252 6 258
Negative 26 110 136 15 121 136
Total 277 117 394 267 127 394
a

S/P ratio cutoffs: positive, ≥0.27; negative, <0.27.

b

For better statistical analysis, the S/P ratio cutoffs of the commercial kit were adjusted as follows: positive, ≥0.35; negative, <0.35 (the original S/P ratio cutoffs were positive, ≥0.40; equivocal, ≥0.30 and <0.40; negative, <0.30).