Table 2.

Dose-volumetric parameters when 48 Gy was prescribed at the isocenter

Group IC dose [Gy] ITV
PTV
Lungs
D95 [Gy] Min dose [Gy] Max dose [Gy] D95 [Gy] Min dose [Gy] Max dose [Gy] HI Mean dose [Gy] V20 [%] V5 [%]
BPL 48.0 ± 0.0 46.8 ± 0.8 46.0 ± 1.1 49.8 ± 0.7 45.7 ± 0.8 43.7 ± 1.2 49.9 ± 0.8 1.1 ± 0.0 2.9 ± 0.8 3.8 ± 1.4 14.9 ±4.5
RPL 48.0 ± 0.0 47.8 ± 0.9 47.3 ± 1.2 51.2 ± 1.2 47.4 ± 1.0 46.4 ± 1.3 51.4 ± 1.4 1.1 ± 0.1 3.3 ± 0.8 4.2 ± 1.6 17.2 ± 4.6
XVMC 48.0 ± 0.0 44.5 ± 2.4 42.7 ± 2.8 50.1 ± 1.1 42.1 ± 3.2 39.2 ± 3.2 50.4 ± 1.1 1.3 ± 0.1 3.3 ± 0.8 4.0 ± 1.5 16.8 ± 4.7

Data are shown as means ± SD. IC = isocenter, ITV = internal target volume, PTV = planning target volume, D95 = the dose to cover 95% of the volume, Min dose = Minimum dose, Max dose = Maximum dose, HI = homogeneity index, V20Gy and V5Gy = the percentage of the volume receiving more than 20 Gy and 5 Gy, BPL = the Batho power-law correction, RPL = the radiological path length algorithm, XVMC = the X-ray Voxel Monte Carlo algorithm.