Table 3.

Dose-volumetric parameters when plans were recalculated with RPL and XVMC using the same monitor units of BPL in Table 2

Group IC dose [Gy] ITV
PTV
Lungs
D95 [Gy] Min dose [Gy] Max dose [Gy] D95[Gy] Min dose [Gy] Max dose [Gy] HI Mean dose [Gy] V20 [%] V5 [%]
RPL 50.1 ± 0.8 49.8 ± 1.2 49.3 ± 1.5 53.4 ± 1.3 49.4 ± 1.4 48.4 ± 1.7 53.6 ± 1.4 1.1 ± 0.1 3.5 ± 0.8 4.6 ± 1.8 17.5 ±4.7
XVMC 48.7 ± 0.6 45.1 ± 2.4 43.3 ± 2.9 50.7 ± 1.1 42.7 ± 3.3 39.7 ±3.3 51.1 ±1.2 1.3 ± 0.1 3.3 ± 0.8 4.1 ± 1.5 16.9 ± 4.8

Data are shown as means ± SD. IC = isocenter, ITV = internal target volume, PTV = planning target volume, D95 = the dose to cover 95% of the volume, Min dose = Minimum dose, Max dose = Maximum dose, HI = homogeneity index, V20Gy and V5Gy = the percentage of the volume receiving more than 20 Gy and 5 Gy, BPL = the Batho power-law correction, RPL = the radiological path length algorithm, XVMC = the X-ray Voxel Monte Carlo algorithm.