Table V.
Speed (mph) |
Windows | Ventilation System |
Air Exchange Ratesb ACH (h−1) |
Predicted PM2.5 Concentrationsc(μg/m3) |
---|---|---|---|---|
20 | One fully Open | AC Off | 78.6 | 8 |
60 | One Open 3 inches | AC Off | 56.4 | 11 |
60 | All Closed | AC Regular | 38.6 | 16 |
20 | One Open 3 inches | AC Off | 20.9 | 29 |
0 (parked) | One Fully Open | AC Off | 19.2 | 31 |
60 | All Closed | AC Max | 5.1 | 118 |
20 | All Closed | AC Max | 3.0 | 201 |
Simulation assumptions: V = 4 m3, Ecig = 13800 μg/cig, Rcig = 1.05 cig/h, t = 10 min, T = 60 min, and ACH as shown.
Air exchange rates were obtain from Ott et al. (2008).(43)
PM2.5 concentrations are calculated based on the mass balance Equation (3).