Skip to main content
. 2012 Jul 24;12:94. doi: 10.1186/1471-230X-12-94

Table 2.

Test characteristics of single and double FIT sampling (OC-sensor) for colorectal cancer and advanced adenoma at a cut-off level of 50 ng/ml in asymptomatic, high-risk subjects referred for surveillance colonoscopy

 
Single FIT(n= 1041)
Double FIT (one FIT+)(n= 451)
  CRC§ (n= 5) Advanced adenoma(n= 101) CRC§ (n= 2) Advanced adenoma(n= 40)
Sensitivity
80%
28%
50%
33%
N
4/5
28/101
1/2
13/40
(CI in %)
(28–99)
(19–38)
(1–99)
(19–49)
Specificity
89%
91%
81%
82%
N
925/1036
852/935
363/449
336/409
(CI in %)
(87–91)
(89–93)
(77–84)
(78–86)
PPV*
3%
24%
1%
15%
N
4/115
28/115
1/87
13/87
(CI in %)
(1–9)
(17–33)
(0,03–6)
(8–24)
NPV
99,9%
92%
99,7%
93%
N
925/926
853/926
363/364
337/364
(CI in %) (99–100) (90–94) (98–99,9) (89–95)

* PPV: positive predictive value.

† NPV: negative predictive value.

§ CRC: colorectal cancer.

‡ Advanced adenoma: Adenomas ≥1.0 cm, with any villous features (i.e. tubulovillous or villous adenoma) or high-grade dysplasia.