Skip to main content
. 2012 Sep 10;7:152. doi: 10.1186/1748-717X-7-152

Table 1.

Critical organ dose-volume limits for stereotactic ablative radiotherapy to 50 Gy given in 4 fractions

Organ, Limit, and Volume Maximum dose limits
Esophagus
Dmax
35 Gy
≤ 1 cm3
30 Gy
≤ 5 cm3
20 Gy
Brachial plexus
Dmax
40 Gy
≤ 1 cm3
35 Gy
≤ 5 cm3
30 Gy
Trachea
Dmax
45 Gy
≤ 1 cm3
35 Gy
≤ 5 cm3
30 Gy
Main bronchus and bronchial tree
≤ 1 cm3
40 Gy
≤ 5 cm3
35 Gy
Heart
≤ 1 cm3
40 Gy
≤ 5 cm3
35 Gy
Total lung volume*
V20 Gy(RBE)
< 20% of total lung volume
V10Gy(RBE)
< 30% of total lung volume
V5Gy(RBE)
< 40% of total lung volume
Major vessels
Dmax
45 Gy
≤ 1 cm3
40 Gy
≤ 5 cm3
35 Gy
Skin
≤ 1 cm3
35 Gy
≤ 5 cm3
30 Gy
Chest wall
≤ 10 cm3
45 Gy
≤ 30 cm3
35 Gy
Spinal cord
Dmax
25 Gy
≤ 5 cm3 20 Gy

*Defined as right plus left lungs minus the gross tumor volume.