Skip to main content
. Author manuscript; available in PMC: 2012 Sep 19.
Published in final edited form as: J Neural Eng. 2010 Jan 14;7(1):16003. doi: 10.1088/1741-2560/7/1/016003

Table 3.

Increase of the results on the testing data set (in percent of r2) by using the sigmoid function to compute the relative position of the target. The values in bold are significant (p<0.05). (The multiple linear regression technique was used with the sliding windows approach, two electrodes and features selection.)

User A B C D E F G H Mean
Increase (%) −1.53 8.22 1.5 −3.49 3.12 23.9 5.77 7.7 5.4
Confidence Interval at 95% −3.8; 0.8 −0.4; 17 −3.3; 7.7 −2.2; 9.1 2.3; 4.6 −1.9; 56 2.7; 9.7 3.6; 11.9 4.1; 6.7