Skip to main content
. 2012 Aug 10;3(9):2078–2086. doi: 10.1364/BOE.3.002078

Table 1. Material qualities of plastics tested for detector case [22].

Tensile Strength (MPa) Flexural Modulus (GPa) NIR Attenuation Coefficient (cm−1) X-Ray Attenuation Coefficient (cm−1)
Polycarbonate 62 2.4 0.66 0.35
Polypropylene 35 1.4 0.91 0.29
Acrylic 60 3.0 1.08 0.68
High Density Polyethylene 35 0.3 1.56 0.32
Acetal 61 2.5 2.18 0.89
Acetal Resin 69 2.8 2.00 1.05
Polytetrafluoroethylene 25 0.6 3.31 2.26