Pulse sequence parameters used in the study

Dataset Protocol name Protocol type TR (ms) TE (ms) Flip angle No. Slices Scan time (sec) in-plane resolution (mm2) Phase encoding direction Slice thickness (mm) Slice gap (mm) FCa SBD
Initial comparing T1-weighted protocols
A
FLASH
25
4.6
30
160
408
1.0x1.0
Right-left
2.0
−1
-
-
 
B
MPRAGE
9.8
4.6
8
120
279
1.16x1.1
Right-left
1.2
0
-
-
 
C
MPRAGE
7.6
3.5
8
160
614
1.0x1.0
Anterior-posterior
1.0
0
-
-
 
D
MPRAGE
7.6
3.5
8
160
614
1.0x1.0
Anterior-posterior
1.05
0
-
-
 
E
MPRAGE
9.8
4.6
8
120
279
1.16x1.1
Right-left
1.2
0
-
-
 
F
MPRAGE
7.1
3.3
8
145
557
1.0x1.0
Anterior-posterior
1.1
0
-
-
Optimizing T1-weighted protocols
F
MPRAGE
7.1
3.3
8
145
557
1.0x1.0
Anterior-posterior
1.1
0
-
-
 
F1
MPRAGE
7.1
3.3
8
145
557
1.0x1.0
Anterior-posterior
1.1
0
-

 
F2
MPRAGE
7.1
3.3
8
145
557
1.0x1.0
Right-left
1.1
0
-
-
 
F3
MPRAGE
7.1
3.3
8
145
557
1.0x1.0
Right-left
1.1
0
-

 
C1
MPRAGE
9.5
5.3
8
160
614
1.0x1.0
Anterior-posterior
1.0
0

-
 
C2
MPRAGE
7.6
3.5
8
160
614
1.0x1.0
Anterior-posterior
1.0
0
-

  C3 MPRAGE 10 5.6 8 160 614 1.0x1.0 Right-left 1.0 0 -

FCa: Flow Compensation, manufacturer's default settings.

SBD: Saturation band, manufacturer's default settings.