Effect of cycle duration upon the degradation of Adenovirus DNA

Exposure time Mean Cycle Threshold (CT) valuea(n = 4)
Stainless steel sheet Ceramic tile
0 min (control)
17
18
1 min
22
22
2 min
25
27
3 min
27
27
4 min
33
34
5 min
31
45
6 min 45 45

aA 3.3 CT increase equates to a 1 log reduction in detectable viral genome. A CT value of 45 is the assay end-point and when DNA is considered undetectable.