Skip to main content
. 2001 May;12(5):1481–1498. doi: 10.1091/mbc.12.5.1481

Table 2.

Kinetic rates of VIP36-SP-GFP recycling between the Golgi and ER

Experiment Transport rate constants (% · min−1)
t1/2a (min)
Exchange timea (min)
ER→Golgi Golgi→ER ER→Golgi Golgi→ER ER→Golgi Golgi→ER
ER bleach (n = 10) 1.22b  ± 0.66 7.60c  ± 2.24 113 ± 70 1.36  ± 0.45 178  ± 106 17.3  ± 5.0
Golgi bleach (n = 9) 1.23c  ± 0.59 7.74b  ± 3.14 98.1 ± 40.4 1.94  ± 0.75 160  ± 66 22.2  ± 8.6
Combined 1.22  ± 0.44 7.68  ± 1.94 105 ± 39 1.67  ± 0.45 169  ± 59 19.9  ± 5.1

Intervals are 90% confidence for the number of trials shown. 

a

 Calculated for each experiment and then averaged. 

b

 Transport rates calculated from the fitted curves and steady-state fraction (see MATERIALS AND METHODS). 

c

 Transport rates derived directly from the fitted curve.