Skip to main content
. 2012 Sep 21;6:1539–1545. doi: 10.2147/OPTH.S36331

Table 1.

Comparison of mean deviation (MD) change and MD slope

Before 3 months 6 months 9 months 12 months P value MD slope (dB/year)
Operative eyes (dB) −19.7 ± 5.6 −19.6 ± 5.7 −20.3 ± 5.4 −19.8 ± 5.3 −20.4 ± 5.1 0.194 −0.26 ± 0.64#
Nonoperative eyes (dB) −8.8 ± 8.0 −10.2 ± 8.4 −9.3 ± 8.3 −9.8 ± 8.8 −9.5 ± 8.4 0.011 −0.65 ± 0.70#

Notes: Values are mean ± standard deviation. P values were derived by ANOVA for repeated measures.

#

P = 0.047 (Mann-Whitney U-test).