Skip to main content
. Author manuscript; available in PMC: 2013 Jun 12.
Published in final edited form as: Circulation. 2012 May 14;125(23):2844–2853. doi: 10.1161/CIRCULATIONAHA.111.060889

Table 2.

Echocardiographic parameters of patients before and after LVAD implantation.

Pre-VAD Post-VAD p-value
LVEDD (mm) 69 ± 12 55 ± 15 <0.0001
LVESD (mm) 63 ± 13 48 ± 17 <0.0001
LVEF (%) 17 ± 2 25 ± 15 0.003
IVS (mm) 10 ± 3 11 ± 2 NS
PWT (mm) 10 ± 2 11 ± 2 NS