Table 1.

Selected generation data and sequence of images for dual-layer microbubbles produced under varying input flow conditions. Scale bar is 50 μm.

4 Channel 8 Channel

Lipid (μl min−1) N2 (PSI) Rate (Hz) Diameter (μm) PDI ϕ Lipid (μl min−1) N2 (PSI) Rate (Hz) Diameter (μm) PDI ϕ
140 10 16000 24.6 ± 1.0 4.0 19 220 9 16400 28.5 ± 2.5 8.8 18
160 10 14200 21.9 ± 0.9 4.0 34 220 11 22200 28.5 ± 2.0 7.0 14
160 11 52200 20.4 ± 1.1 5.3 11 240 11 31900 25.1 ± 1.7 6.6 15
180 12 64700 18.6 ± 1.7 9.1 14 240 12 103300 21.8 ± 1.2 5.7 7
240 17 65800 22.3 ± 1.7 7.6 10 280 12 107000 21.2 ± 1.8 8.3 9