Table 1.

Characteristics of Progressed and Nonprogressed Eyes Based on Stereophotograph Assessment

Progressors (n = 16) Nonprogressors (n = 221) P
Age (yrs), mean (95% CI) 68.1 (53.1–83.2) 66.1 (41.5–90.7) 0.11
Right eye (%)* 8 (50%) 115 (52%) 0.84
Baseline abnormal disc by stereophotography (%)* 13 (81.3%) 101 (45.7%) <0.05
Baseline HRT cup disc area ratio 0.47 (0.37–0.56) 0.34 (0.30–0.37) <0.05
Baseline disc area (mm2) 2.07 (1.92–2.22) 1.95 (1.88–2.03) 0.29
Baseline MRA any sector ONL (%)* 13 (81.3%) 80 (36.2%) <0.05
Baseline global MRA ONL (%)* 8 (50%) 34 (15.4%) <0.05
Baseline visual field repeatable abnormal result (%)* 7 (43.8%) 74 (33.5%) 0.41
Baseline visual field mean deviation (dB) −1.17 (−5.45 to −0.29) −0.87 (−2.33 to −0.07) 0.44
Baseline visual field PSD (dB) 2.17 (1.7–9.16) 1.73 (1.43–2.48) <0.05

CI = confidence intervals

HRT = Heidelberg retina tomograph

MRA = Moorfields regression analysis

ONL = outside normal limits

PSD = pattern standard deviation.

*

Number of eyes (%) – P value based on chi-square.

Mean (95% CI) – P value based on t test.