Pre-operative localization studies at NIH (n = 163)

n %
Patients who underwent operation with non-invasive studies only 71 44
Patients who underwent operation with at least one non-invasive study 92 56
Localization study (%) Number performed (%) True positive (%) False positive (%) PPV
Non-invasive
Neck ultrasound (US) 161 (99) 97 (60) 19 (11) 84
Sestamibi 163 (100) 113 (69) 5 (3) 96
CT, neck/chest 162 (99) 78 (48) 21 (13) 79
MRI, neck/chest 157 (96) 66 (42) 17 (11) 80
Invasive
US or CT guided FNA 15 (9) 12 (80) 0 (0) 100
Arteriogram 80 (49) 49 (61) 4 (5) 92
Arterial stimulation venous sampling 72 (44) 34 (47) 3 (4) 92
Selective venous sampling 37 (23) 27 (73) 5 (14) 84