Skip to main content
. Author manuscript; available in PMC: 2012 Oct 12.
Published in final edited form as: AJR Am J Roentgenol. 2011 Apr;196(4):816–823. doi: 10.2214/AJR.10.4907

Appendix 2.

Organ-specific radiation dose estimates (mGy) from a single CT colonography screen

a) Females
Manufacturer and CT scanner
GE GE Siemens Siemens Toshiba Toshiba Philips Philips Philips
16 64 16 64 16 64 16 40 16
Organ Slice Slice Slice Slice Slice Slice Slice Slice Slice Mean
Stomach 15 14 13 10 17 16 11 9 8 13
Colon 14 13 12 10 16 15 10 8 8 12
Liver 14 14 12 10 17 16 10 9 8 12
Pancreas 12 12 11 8 14 14 9 7 7 10
Lung 2 3 2 2 3 6 2 2 2 3
Breast 1 1 1 1 1 5 1 1 1 1
Ovary/uterus 14 13 12 9 16 14 10 8 7 11
Bladder 15 14 13 10 17 16 11 9 8 12
Kidney 16 15 13 11 18 17 11 9 8 13
Bone marrow 7 7 6 5 8 8 5 4 4 6

Effective Dose (mSv) 10 9 8 7 11 11 7 6 5 8
b) Males
Manufacturer and CT scanner
GE GE Siemens Siemens Toshiba Toshiba Philips Philips Philips
16 64 16 64 16 64 16 40 16
Organ Slice Slice Slice Slice Slice Slice Slice Slice Slice Mean
Stomach 15 14 12 10 17 16 10 9 8 12
Colon 14 13 12 9 16 14 10 8 7 11
Liver 14 13 12 9 16 15 10 8 8 12
Pancreas 11 11 10 8 13 13 8 7 6 10
Lung 2 2 2 1 3 5 1 1 2 2
Prostate 4 9 5 5 9 15 3 5 7 7
Bladder 14 13 12 9 16 15 10 8 8 12
Kidney 15 14 13 10 17 16 11 9 8 13
Bone marrow 6 6 5 4 7 7 5 4 4 5

Effective Dose (mSv) 7 8 6 5 9 10 5 5 5 7