Floor Photo Thickness (mm) Footfall deflection (mm) Density (kg/m3)
Rigid (Control) graphic file with name nihms2428t1.jpg 2
SmartCell graphic file with name nihms2428t2.jpg 25 0.8 1120
SofTile graphic file with name nihms2428t3.jpg 100 4.0 1057
Firm-Foam graphic file with name nihms2428t4.jpg 110 85.4 32
Soft-Foam graphic file with name nihms2428t5.jpg 100 92.4 22.2