Parameters for Kv conductances in the model

 
Steady-state conductance (mean ± SD)
Time constant (mean ± SE)
  gmax(nS) V50(mV) slope(mV) P α(s-1) slope(V-1) β(s-1) τo(ms)
KDR (n = 6)
78 ± 22
-31 ± 9
12.0 ± 2.0
1
4 ± 1
43 ± 6
156 ± 53
1 ± 2
KA act. (n = 5)
36 ± 29
-43 ± 4
8.4 ± 1.6
2
*
*
*
*
KA inact. (n = 4) - -85 ± 1 -11.3 ± 2.9 1 341 ± 101 -44 ± 4 0.21 ± 0.07 0 ± 2

*) KA activation time constant was fixed at 1.5 ms.

gmax = maximum conductance, V50 = half activation/inactivation voltage, slope = slope factors for the steady-state parameters (Eq. 2) or time constant (Eq. 3), P = order for the steady-state parameter (Eq.2), α and β = activation and deactivation rates for Eq. 3, τ0 = offset for bell function (Eq. 3).