Skip to main content
. 2012 Jul 13;(65):3978. doi: 10.3791/3978
Operation Parameters Standard Methods Index Typical Range Extreme Range
    Mesophilic Thermophilic Mesophilic Thermophilic
Temperature 2550(A) 32-37 17 °C 50-60 17 °C 20-42 17 °C 45-65 17 °C
Organic Loading Rate NL 0.8-2.0 17 g VS-L-1-d-1 1.5-5.0 17 g VS-L-1-d-1 0.4-6.4 17 g VS-L-1-d-1 1.0-7.5 17 g VS-L-1-d-1
Hydraulic Retention Time NL 15 - 35 Days < 15 ; > 35 Days
Carbon: Nitrogen Ratio NL 25:1 17 > 25:1
Monitoring Parameters Standard Methods Index Optimum Range Suboptimum Range
pH 4500-H+(B) 6.5 - 8.2 10 < 6.5 ; > 8.2
Alkalinity 2320(B) 1300 - 3000 17 mg CaCO3-L-1 < 1300 mg CaCO3-L-1
Volatile Acids 5560(C) < 200 10 mg Ac-L-1 > 200 10 mg Ac-L-1
Solids Removal Efficiency 2540(B,E) > 50 % < 50 %
Biogas Content 2720(C) 55-70 CH4; 30-45 CO2 % < 55 CH4; > 45 CO2 %