Component
|
Specifications (Design Considerations)
|
Comments
|
Temperature-Controlled Circulating Water Heater |
Temperature Range: 25-65 °C
(Heating Capacity, Max. Pressure Head, Volumetric Flow Rate) |
Heated water must be supplied at a sufficiently high flow rate and with sufficient pressure to fully circulate. |
Sampling Port |
NA |
Located close to headspace is ideal. |
Foam Trap |
Volume: 25% of Reactor Volume |
Simple side-arm flask or glass jars can be used. The unit should be accessible for cleaning. |
Hydrogen Sulfide Scrubber |
(Gas Contact Time) |
Glass or plastic tubes should be used (not metal). Sizing length should provide adequate gas contact time. |
Gas Reservoir |
Volume: > 2x Effluent Volume; Material: Semi-Elastic (not Rigid) |
The volume should exceed that taken during effluent decanting. The material should allow for shrinking and expansion. |
Bubbler |
NA |
The head pressure provided by the water level should be minimized to limit pressure build-up in the gas delivery system. |
Gas Meter |
(Gas Flow Detection Range) |
Plastic gas meters are preferred over metal. The gas flow detection range should be accurate at expected biogas production rates. |