Skip to main content
. 2012 Nov;82(5):910–917. doi: 10.1124/mol.112.080259

TABLE 1.

Single-channel kinetics

Numbers of patches selected as being suitable for burst analysis were as follows: ACh, n = 3; ACh + TQS, n = 11; 4BP-TQS, n = 13; and ACh + 4BP-TQS, n = 7. Data are means ± S.E.M.

Agonist Open Time Shut Time Open Probability Burst Length Open Time within Burst
ms
ACh (n = 9) 1.49 ± 0.28§ 4113 ± 1419§§§ 0.0004 ± 0.0015§ 3.28 ± 2.24§ 2.00 ± 1.26
ACh + TQS (n = 14) 24.7 ± 5.8††† 379 ± 103*** 0.13 ± 0.04††† 165 ± 55 141 ± 42
4BP-TQS (n = 20) 245 ± 68* 532 ± 184*** 0.32 ± 0.09* 1228 ± 364* 1207 ± 360
ACh + 4BP-TQS (n = 8) 330 ± 56** 590 ± 135*** 0.36 ± 0.09††† 3099 ± 754**, 2845 ± 745**,§

Significant differences (determined by ANOVA) to ACh (* P < 0.05; ** P < 0.01; *** P < 0.001) or to 4BP-TQS (§ P < 0.05; §§§ P < 0.001) are indicated. Otherwise, significant differences determined by pairwise comparisons to ACh (††† P < 0.001) or to 4BP-TQS ( P < 0.05) are indicated.