Skip to main content
. 2012 Jul 30;590(Pt 18):4571–4584. doi: 10.1113/jphysiol.2012.233015

Table 1.

The optimal parameter set for each specimen, the associated RMS errors and R2 values, along with the statistical summary for all seven specimen and the optimal parameter set that represents the average response

β a1 a2 a4 RMS error R2
Specimen 1 2.39 52.3 34.5 16.2 0.61 0.91
Specimen 2 2.55 23.7 29.3 7.80 0.64 0.94
Specimen 3 2.62 33.1 18.9 7.60 0.54 0.97
Specimen 4 2.55 23.2 25.8 10.6 0.96 0.95
Specimen 5 2.09 16.3 16.5 6.60 1.00 0.91
Specimen 6 2.24 116.9 13.0 6.54 1.01 0.91
Specimen 7 1.85 20.1 12.8 7.85 1.13 0.91
Mean ± SEM 2.33 ± 0.11 40.8 ± 13.5 21.5 ± 3.2 9.03 ± 1.3 0.84 ± 0.09 0.93 ± 0.01
Average response 2.25 33.7 23.2 9.82

While a representative response cannot be obtained by averaging individual parameter values, the average and associated standard error of the mean of each parameter are provided to demonstrate the consistency of identified parameters across all specimens.