Skip to main content
. Author manuscript; available in PMC: 2012 Nov 2.
Published in final edited form as: J Nucl Med. 2011 Oct 11;52(11):1690–1697. doi: 10.2967/jnumed.111.092767

Table I.

Maximum diameters measurements on pathology and image delineations for all 17 patients. Pearson correlation (r) coefficients are given along with P values and 95% confidence intervals (CI) for r.

Measurements (cm) according to each delineation
Pathologic CT1(Manual) CT2(Manual) PET(Manual) PET(T50) PET(A1) PET(A2) PET(FLAB)
Patients 1 6.2 6.6 6.7 5.7 4.6 5 4.8 5.8
2 2.7 3.3 3.3 3.4 2.8 3.1 2.8 3
3 9 10.5 10.1 8.9 7 7.5 7.7 9.2
4 1.5 1.8 1.9 2.1 1.3 1.6 1.3 1.5
5 1.8 3.4 3.4 2 1.2 1.4 1.3 1.6
6 3.1 4 3.9 3.2 2.4 2.6 2.5 2.8
7 4.3 5 5.1 4.5 3.8 3.9 3.8 3.9
8 3.1 5.7 5.7 5.1 2.8 4 3.7 3.5
9 3.5 3.9 4 3.4 2.7 2.9 3 3.1
10 5.7 7.6 7.7 7.4 7.5 4.7 6.7 5.4
11 5 5.1 5.3 4.7 2.7 3 2.9 4.6
12 2.8 3.5 3.2 3.2 2.4 2.5 2.6 2.8
13 4.1 5.2 5.1 4.3 3.2 3.3 3.3 4
14 4 4.8 4.9 3.7 3.2 3.4 3.2 3.9
15 7 7.4 7.4 5.8 6.2 6.5 6.3 6.7
16 2.3 2.3 2.4 2.1 1.8 1.7 1.9 2.1
17 2.5 6 5.9 4.5 2.5 2.7 2.6 2.2
Statistics Mean±STD 4.0±2.0 5.1±2.2 5.1±2.1 4.2±1.9 3.4±1.9 3.5±1.6 3.6±1.8 3.9±2.0
Median 3.5 5.0 5.1 3.7 2.8 3.1 3.0 3.5
Range 1.5–9 1.8–10.5 1.9–10.1 1.9–8.9 1.2–7.5 1.4–7.5 1.3–7.7 1.5–9.2
Pearson r - 0.90 0.91 0.95 0.89 0.95 0.93 0.99
95% CI for r - 0.74–0.96 0.76–0.96 0.86–0.98 0.72–0.96 0.85–0.98 0.81–0.98 0.98–1.00
P - <0.0001 <0.0001 <0.0001 <0.0001 <0.0001 <0.0001 <0.0001