Table 3.

Arithmetic Mean (SD)(range) or Geometric mean (GSD)(range).of concentrations in the family room of study homes.

Exposures Remediation In-Progress n/N Remediation Completed n/Nb
Asbestos (Fibers/cc) 0.02(0.01) (0.01–0.06) 13/21 0.03(0.02) (0.01–0.08) 27/47
Lead (mg/m3) <Quantitation Limit 0/24 <Quantitation Limit 0/49
Radon (pCi/L) a 2.4(3.0) (<0.3–18.9) 14/24 2.3(2.2) (<0.3–11.2) 37/45
CO (ppm) 0.03(0.16) (0–0.80) 1/24 0.14(0.42) (0–2.3) 6/49
CO2 (ppm) 560(210) (300–1240) 24/24 860(470) (380–2900) 49/49
Relative Humidity (RH%) 42(8.8) (28–65) 24/24 37(10) (20–67) 49/49
Temperature (°C) 17(4.5) (8–25) 24/24 20(2.7) (9–25) 49/49
Wall Moisture (%) 15.1(2.3) (7–20) 24/24 15.6(3.3) (14–22) 47/49

GSD: Geometric Standard Deviation

a

Geometric mean (GSD)(range).

b

Number detected (n)/Total number analyzed (N)