Skip to main content
. Author manuscript; available in PMC: 2012 Nov 1.
Published in final edited form as: Med Image Comput Comput Assist Interv. 2011;14(Pt 3):215–222. doi: 10.1007/978-3-642-23626-6_27

Table 1.

Accuracy (Az) of the CAD system with given feature sets.

Features Dimension Patch Size # of patches (TIB) # of patches (Normal) Area under ROC curve: Az

Shape & GLCM 8+18=26 17×17 14144 12032 0.8991
Shape & GLCM 8+18=26 13×13 24184 20572 0.9038
Shape & GLCM 8+18=26 9×9 50456 42924 0.9096

Shape 8 17×17 14144 12032 0.7941
Shape 8 13×13 24184 20572 0.7742
Shape 8 9×9 50456 42924 0.7450

Steer. Wavelets& Shape 6×17×17+8=1742 17×17 14144 12032 0.7846
Steer. Wavelets& Shape 6×13×13+8=1022 13×13 24184 20572 0.7692
Steer. Wavelets& Shape 6×9×9+8=494 9×9 50456 42924 0.7908

Steer. Wavelets 6×17×17=1734 17×17 14144 12032 0.7571
Steer. Wavelets 6×13×13=1014 13×13 24184 20572 0.7298
Steer. Wavelets 6×9×9=486 9×9 50456 42924 0.7410

GLCM 18 17×17 14144 12032 0.7163
GLCM 18 13×13 24184 20572 0.7068
GLCM 18 9×9 50456 42924 0.6810