Table 2. Correlation coefficients for different feature sets.

L2 on features L2 on reduced features Gaussian kernels on reduced features
Fourier-based Spectrum - - 0.69
Auditory Spectrum 0.473 - 0.739
Global Spectro-temporal Modulations 0.509 - 0.701
Separable Spectro-temporal Modulations 0.561 0.561 0.830
Full cortical Model 0.611 0.607 0.944
Neurophysiological STRFs - - 0.73

Each row represents the correlation coefficient between the model and human similarity matrix using a direct Euclidian distance the specific feature itself (left); on a reduced dimension of the features (middle column) or using the Gaussian kernel distance (right column). Auditory Spectrum: time-average of the cochlear filterbank; Global Spectro-temporal Modulations: model STRFs averaged in time and frequency; Separable Spectro-temporal modulations: model STRFs averaged separately in rate and scale, and then in time; Full cortical model: STRFs averaged in time; Neurophysiological STRFs: as the full cortical model, but with STRFs collected in primary auditory cortex of ferrets.