Skip to main content
. 2012 Sep 1;4(6):1081–1086. doi: 10.3892/etm.2012.731

Table II.

Limit loads of the five internal fixation techniques.

Internal fixation technique n Limit load, mean ± SD (N)
Circular wiring 4 35.14±2.46
Figure of eight wiring 4 56.61±1.97a
Figure of eight plus circular wiring 4 81.43±2.61b,c
Kirschner tension band 4 84.45±2.52b,c
Screw fixation 4 57.62±2.91a
a

P<0.05 compared with circular wiring;

b

P<0.01 compared with circular wiring;

c

P<0.05 compared with figure of eight wiring or screw fixation.