Abstract
Background
Human papillomaviruses (HPV) are classified into high-risk HPV and low-risk HPV. The most common high-risk HPV types in cervical cancer are HPV 16 and 18, and the most common low-risk types causing genital warts are HPV 6 and HPV 11. In this study, applying novel AllGlo fluorescent probes, we established a quadruplex quantitative PCR method to simultaneously detect and differentiate HPV 6, 11, 16 and 18 in a single tube.
Methods
The specificity, the sensitivity, the detection limit, the reproducibility and the standard curve of this method were examined. Finally, clinical samples that had been tested previously by TaqMan PCR and HPV GenoArray (GA) test were used to verify the accuracy and sensitivity of the method.
Results
The assay has a sensitivity of 101 to 102 copies/test and a linear detection range from 101 to 108 copies/test. The mean amplification efficiencies for HPV 6, 11, 16, and 18 were 0.97, 1.10, 0.93 and 1.20, respectively, and the mean correlation coefficient (r2) of each standard curve was above 0.99 for plasmid templates ranging from 103 to 107 copies/test. There was 100% agreement between the AllGlo quadruplex quantitative PCR, HPV GA test and TaqMan uniplex qPCR methods.
Conclusions
AllGlo quadruplex quantitative PCR in a single tube has the advantages of relatively high throughput, good reproducibility, high sensitivity, high specificity, and a wide linear range of detection. The convenient single tube format makes this assay a powerful tool for the studies of mixed infections by multiple pathogens, viral typing and viral load quantification.
Introduction
More than 120 Human papillomaviruses (HPV) genotypes have been found throughout the world. The most common high-risk HPV types in cervical cancer are HPV 16 and 18, and the most common low-risk types causing genital warts are HPV 6 and HPV 11 [1]. Some studies suggest that about 70% of cervical epithelial cell dysplasia and cervical cancer is closely related to HPV 16 and 18 infection, while more than 90% of external genital warts is caused by HPV 6 and 11 infection [2], [3]. HPV 16 and 18 are regarded as high-risk HPV, while HPV 6 and 11 are thought as low-risk HPV [4]–[6]. A persistent infection may generate a particularly high HPV DNA load through viral replication [7]–[9]. Because HPV 6 or 11 can cause genital warts and HPV 16 or 18 may lead cervical cancer, preventing infections from these viruses can be an effective way to control the incidence of cervical cancer and cauliflower excrescence. A natural HPV-infection gives little or none protection against new infections due to low immune response, but the HPV-vaccine does.Several HPV vaccines are commercially available [10]–[16] and have been shown to be effective in preventing infections caused by HPV 6, 11, 16 and 18, There are already several commercial tests for HPV 6, 11, 16 and 18 available. It is obvious a marked progression for these tests. This assay will facilitate molecular epidemiological studies and drug development.
HPV genotyping is mainly determined by molecular methods of detecting viral DNA [17]–[21]. The multiplex real-time fluorescence quantitative PCR (qPCR) technique is an effective method which can simultaneously type many viruses [22–24]. However, existing qPCR has some disadvantages such as low throughput [25,26], complicated techniques [27,28], and expensive reagents [27,29]. Moreover, it was not able to type four HPV viruses simultaneously in a single tube in a quantitative manner [26] in order to meet the requirement for detecting multiple subtypes of HPV in a clinical setting.
The AllGlo probe is the latest generation of fluorescent quantitative probes developed by AlleLogic Biosciences Corporation (Hayward, California). It replaces the quencher with a fluorophore that is identical the first fluorophore. Both of the fluorophores are in a quenched state when the probe is intact, but become dequenched when the probe is cleaved. An AllGlo probe generates two light-emitting fluorophores per cleavage event, leading to greater fluorescence gain in fluorescence PCR and lower Ct value (Figure 1). In addition, the optimal Tm of the oligonucleotide of the AllGlo probe is the same temperature for annealing/extension, not ten degrees higher as is required for TaqMan. As a result, AllGlo probes tend to be shorter, usually 15–16 nucleotides long. This short oligonucleotide is advantageous in single mismatch discrimination. So AllGlo quadruplex quantitative PCR has the advantages of relatively high throughput, good reproducibility, high sensitivity, high specificity, it is easy for designing the probes and primers of multiplex qPCR and can increase the detection throughput.
In this study, we used AllGlo probe and developed a method to simultaneously detect four types of HPV (HPV 6, 11, 16, 18) in a single-tube format. This quadruplex assay was validated with an existing uniplex TaqMan assay and a HPV GA test. We carried out a series of control experiments and demonstrated the high specificity, sensitivity, and repeatability of this approach.
Methods
Clinical Specimens
Clinical specimens which included vaginal secretions (220 specimens), leucorrhoea (30 specimens), cauliflower excrescence warts (200 specimens), and other tissues (10 specimens)were collected from Hangzhou First People’s Hospital, China. The patients(210 M, 250F) aged 20 to 50 years.Informed written consent to utilize their specimens for this study was obtained from the patients (Approved by the Ethics Review Committee of Hangzhou First People’s Hospital). After pre-treatment, all of the specimens were subject to DNA extraction, to detection of HPV genotype by HPV GA test (Hybribio Ltd., Hong Kong), and then to quantitative detection of viral loads (only HPV 6, 11, 16 and 18) by fluorescence quantitative PCR (Da’an reagent, Guangzhou Da’an Diagnostic Co., Ltd., China). The positive samples with known concentrations were conserved at –80 °C for future use.
Construction of Plasmids Containing HPV Genes
We used PCR to gain anticipated size of DNA fragments for each HPV target gene (Table 1) and then ligated to PMD-19T plasmids at 16°C overnight. The ligated products were transformed into E. coli DH5α and plated on LB plates containing l00 mg/L ampicillin. Plasmid DNA was extracted from bacterial culture using an extraction kit (TaKaRa reagent). The plasmid insert DNA sequences (Supporting Information S1) were confirmed by Sanger sequencing (Invitrogen Biotechnology Shanghai, China). The plasmid DNA samples from positive clones were quantified by UV spectrophotometry. Plasmids were diluted to 1010 copies/µl in TE (pH 8.0) buffer for storage at –20°C.
Table 1. Primers and probes of four types of HPV for AllGlo quadruple quantitative PCR.
Gene ID | Targetgene | Primers | Primer sequences | Probe | Product Length (Bp) |
FM897165.1 | L1 | HPV6FHPV6R | GTTATCGCCTCCCCCAAAT ATCTGGCTTTTCCTTTTCAGG | URA-CCATTACCTGTCAAAAGCCCAC-URA | 103 |
AF217526.1 | L1 | HPV11FHPV11R | TTGCGAAAGGAACAAATGTTT GGAAGACACCAATGAGCCACT | MAR-TGGGGGAACCTGTGCC-MAR | 159 |
EU869318.1 | E6 | HPV16FHPV16R | AGGACCCACAGGAGCGAC AGTCATATACCTCACGTCGCAGT | NEP-ATGCACAGAGCTGCAAACAA-NEP | 126 |
EU834744.1 | L1 | HPV18FHPV18R | GGTTCAGGCTGGATTGCG TACACGCACACGCTTGGC | JUP-TCGCAAACGTTCTGCTCC-JUP | 100 |
URA, MAR, NEP and JUP are different AllGlo probe fluorochromes, URA is red fluorochromes, MAR is green fluorochromes, NEP is orange fluorochromes, JUP is yellow fluorochrome. By BLAST sequence comparison, the specificity of primers were depermined.
Extraction of the DNA Template from Clinical Specimens
Secretion swab specimens were dissolved in normal saline. Tissues and cauliflower excrescence warts were infiltrated in 4% sodium hydroxide solution and comminuted with metal bar. The dissolved samples were oscillated and resuspended for 1 min, followed by centrifuging for 5 min (4 °C, 12,000×g/min). The supernatant was discarded, and the sediment was resuspended in 50 µl of DNA extraction solution (Guangzhou Da’an Diagnostic Co., Ltd., China). After heating at 100 °C for 10 min, the sample was centrifuged for 5 min (4 °C, 12,000×g/min). The supernatant was saved for qPCR analyses.
AllGlo Probe Quadruplex Quantitative PCR
Primer and probe design
Conserved regions sequences of the four HPV type-specific genes were obtained from Gene Bank. After sequence comparison by CLUSTRALW software, the most conservative regions were used to design the primers and probes with Primer Premiers 5.0. By BLAST sequence comparison, the primers and probes with the best specificity were selected. The primers and AllGlo probes used in the multiplex qPCR were synthesized by Chaoshi Bio-company (Shanghai, China). To ensure the specificity and sensitivity of the multiplex qPCR, all primers and probes were designed to have similar Tm (Table 1). To enhance the hybridization specificity of each probe to its cognate target sequence, each probe was designed to have at least nine mismatched base pairs with its noncognate targets sequence.
Determination of the specificity and the sensitivity of the primer and the probe
To determine the specificity and the sensitivity of the primer and the probe, the uniplex fluorescence quantitative PCR experiments were first carried out on a Qiagen Rotor Gene 6000 fluorescence quantitative PCR instrument, which can simultaneously detect five wavelengths. Parameter variables such as cycle temperatures, concentration of primers and probe, the detection limit and replicating steps were all optimized. For every reactions, each 25-µl PCR reaction contained 11 µl of deionized water,10 µl of 2 × qPCR Mix (Chaoshi Bio-company, Shanghai, China), 1 µl individual HPV plasmid DNA template(from 102 copies/µl to105 copies/µl), 2 µl primer (1 µl forward primer, 1 µl reverse primer)and 1 µl probe (four primer/probe combinations and concentrations: 400 nM/400 nM, 400 nM/200 nM, 200 nM/200 nM, or 200 nM/100 nM). Each PCR reaction was performed in triplicate. A blank plasmid without an HPV DNA insert and other HPV types DNA (genotypes identified through HPV GA test and Sanger sequencing,except HPV genotypes 6, 11, 16, 18, such as HPV genotypes 32, 39, 52, 58 etc.) was used as a negative control, and deionized water was used as the no-DNA blank control. The cycling conditions were a 5-min incubation at 95°C followed by 45 temperature cycles moving between 95°C for 10 s and 52°C for 20 s (During the cycling phase, the optimization annealing temperatures were varied from 52 to 66°C in single-degree increments). The specificity and sensitivity of primers and probes were determined according to the lowest Ct value, the highest gain in fluorescence and detection limit of the uniplex fluorescence qPCR, and the quadruplex qPCR described in the following sections referred to the parameters of the uniplex fluorescence qPCR.
Optimization of quadruplex quantitative PCR
Thanks to the specificity of the primer and the probe we selected here, we found we could take conditions such as the primer/probe combinations form uniplex assay to multiplex directly. Then we optimized annealing temperature (from 52°C−60°C) and determined the compromise annealing temperature used for multiplex detection was 58?.
Quadruplex quantitative PCR was performed in the same manner as the uniplex qPCR assay described above, PCR mixtures contained 10 µl of 2 × qPCR Mix, 1 µl individual HPV plasmid DNA temple (from 102 copies/µl to105 copies/µl), 8 µl mixture of all four sets of primers and 4 µl mixture of all four sets of probes (four primer/probe combinations and concentrations: 400 nM/400 nM, 400 nM/200 nM, 200 nM/200 nM, or 200 nM/100 nM), 2 µl of deionized water. Other parameter such as cycle temperatures, annealing temperatures and replicating steps were chosen from the uniplex qPCR. Each PCR reaction was performed in triplicate. The negative and blank control test of quadruple qPCR were performed in the same manner as the uniplex qPCR.
Determination of the specificity and sensitivity of quadruplex quantitative PCR
Four individual HPV plasmid DNA stocks and one mixed stock that comprised all four types HPV plasmids DNA were made with concentrations ranging from 1.0 × 101 copies/µl to 1.0 × 105 copies/µl. A 1-µl sample of the stock was used as the template for quadruplex fluorescence quantitative PCR. A blank plasmid without an HPV DNA insert and other HPV types DNA (except HPV genotypes 6, 11, 16, 18, such as HPV genotypes 32, 39, 52, 58 etc.) was used as a negative control, and deionized water was used as the no-DNA blank control. Fluorescence qPCR test was carried out in triplicate to (1) determine the minimum detection limit of this method, (2) determine the detection sensitivity and specificity of fluorescence quantitative PCR for the four types of HPV and (3) construct standard curves.
Standard curve for quadruplex quantitative PCR
Each quantitative PCR reaction, which was used to construct a standard curve, contained mixture of the four types of HPV plasmids (The concentration of each HPV types was equal) at final concentrations (copies/µl) of 103, 104, 105, 106, and 107, as well as primers and probe at optimized concentrations and combinations. The qPCR assay were performed in duplicate, and a standard curve was constructed by the instrument’s software.
The replicability test of quadruplex quantitative PCR
Five aliquots plasmids DNA were made from the mixed stock of four types HPV plasmids and stored at –20 °C, The selected concentrations of each HPV type were 102, 104, 106,and 108(copies/test). Five side-by-side quadruplex quantitative PCR assay were carried out using the aliquots plasmids DNA in triplicate to determine the mean Ct value. The CV% between each aliquot was calculated to determine the replicability of our method.
Detection of clinical specimens
270 clinical samples conserved at –80 °C whose HPV genotype and viral loads (only HPV6, 11, 16 and 18) had been previously determined were divided into nine groups (Table 2), each group contained 30 samples. DNA was extracted from these samples with a Da’an extraction kit (Guangzhou Da’an Diagnostic Co. Ltd., Guangzhou, China.). The extracted DNA was divided into five aliquots. Two aliquots were used for the detection of HPV6–11 and HPV16–18 mixed types by TaqMan uniplex probe fluorescence quantitative PCR (Guangzhou Da’an Diagnostic Co., Ltd., China). The third aliquot was used for the detection of HPV 6, 11, 16 and 18 with AllGlo probe quadruplex fluorescence qPCR. The fourth aliquot was used for the HPV genotype detection with HPV GA test again. The remaining aliquot was conserved at –80 °C to further verify the specificity of the quadruplex fluorescence qPCR method, and the same amount of DNA template was used in each experiment. The result was determined only when all parallel detection results were consistent. Finally, the results obtained by the quadruplex qPCR were compared with the results obtained with the uniplex TaqMan qPCR and HPV GA test.
Table 2. Comparative results of HPV GA test, TaqMan uniplex qPCR and AllGlo quadruplex qPCR.
HPV TYPE | HPV GA test | TaqManuniplex qPCR | AllGlo quadruplexqPCR | ||||||||
6 | 11 | 16 | 18 | others | 6–11 | 16–18 | 6 | 11 | 16 | 18 | |
6 | 28 | 0 | 0 | 0 | 0 | 28 | 0 | 29 | 0 | 0 | 0 |
11 | 0 | 28 | 0 | 0 | 0 | 26 | 0 | 0 | 28 | 0 | 0 |
16 | 0 | 0 | 29 | 0 | 0 | 0 | 27 | 0 | 0 | 28 | 0 |
18 | 0 | 0 | 0 | 28 | 0 | 0 | 26 | 0 | 0 | 0 | 28 |
6+11 | 28 | 29 | 0 | 0 | 0 | 28 | 0 | 28 | 28 | 0 | 0 |
16+18 | 0 | 0 | 27 | 28 | 0 | 0 | 27 | 0 | 0 | 27 | 28 |
6+11+16 | 26 | 27 | 27 | 0 | 0 | 27 | 27 | 27 | 27 | 26 | 0 |
6+11+16+18 | 27 | 27 | 27 | 28 | 0 | 27 | 28 | 28 | 28 | 27 | 29 |
Others# | 0 | 0 | 0 | 0 | 30 | 0 | 0 | 0 | 0 | 0 | 0 |
The agreement rate between AllGlo quadruplex fluorescence quantitative PCR, HPV GA test and TaqMan uniplex qPCR was 100%. Single-tube AllGlo probe quadruplex fluorescence quantitative PCR could simultaneously type HPV 6, 11, 16, and 18 and quantitate the viral load of each HPV at the same time. Compared with the HPV GA test and TaqMan uniplex qPCR method, the AllGlo quadruplex qPCR method enjoys a high sensitivity and a wide linear range. For the same sample, the positive rate and accuracy of the AllGlo quadruplex qPCR method was higher than those of the HPV GA test and TaqMan uniplex qPCR method. #Others:other HPV type,including HPV31,33,35,39,42,43,44,45,51,52,53,56,58,59,66,68,CP8304.
Results
Concentrations and Combinations of the Primer and the Probe, Annealing Temperature
Titrations of primer/probe combinations gave a positive result in uniplex qPCR and Quadruplex qPCR. The 400/200 combination had the highest amplification efficiency and the lowest Ct value (Table 3). The optimum annealing temperatures (°C) for HPV 6, 11, 16 and 18 amplification were: 60, 58, 58 and 58, respectively. In quadruplex fluorescence quantitative PCR, the compromise annealing temperature used for multiplex detection was 58°C, the primer/probe combinations was 400/200 (nM).
Table 3. Comparison of sensitivity and detection limit between TaqMan uniplex qPCR and AllGlo Quadruplex qPCR.
HPVTYPE | 101 copies/test | 102 copies/test | 103 copies/test | 104 copies/test | 105 copies/test | |||||
uniplex qPCR(Ct*) | Quadruplex qPCR (Ct) | uniplexqPCR(Ct) | QuadruplexqPCR (Ct) | uniplex qPCR(Ct) | QuadruplexqPCR (Ct) | uniplex qPCR (Ct) | Quadruplex qPCR (Ct) | uniplex qPCR (Ct) | Quadruplex qPCR (Ct) | |
6 | 0 | 0 | 31.1±2.2 | 31.8±2.3 | 27.2±1.8 | 28.1±1.7 | 24.8±1.6 | 25.1±1.5 | 21.8±1.2 | 21.6±1.3 |
11 | 33.9±1.6 | 34.5±1.8 | 29.6±1.3 | 29.8±1.2 | 25.7±1.1 | 26.1±1.3 | 22.4±0.8 | 22.8±1.0 | 18.9±0.6 | 18.5±0.7 |
16 | 0 | 0 | 30.1±1.6 | 31.1±1.8 | 26.5±1.5 | 26.9±1.7 | 22.9±1.1 | 22.7±1.2 | 19.8±1.0 | 19.9±1.2 |
18 | 33.0±1.9 | 33.5±1.6 | 29.9±1.5 | 30.1±1.6 | 26.1±1.2 | 26.2±1.2 | 22.6±0.9 | 22.1±1.0 | 19.3±0.8 | 18.9±0.9 |
Others# | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Negative | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Others:other HPV type,including HPV31,33,35,39,42,43,44,45,51,52,53,56,58,59,66,68,CP8304.
cycle threshold (Ct) value.
Specificity, Sensitivity and Replicability of Quadruplex Fluorescence Quantitative PCR
All of the four HPV types in quadruplex qPCR were detected positively, while the other type of HPV were negative in the same detection system (Figure 2). The sensitivities (copies/test) for HPV 6, 11, 16, and 18 were 101, 102, 101, and 102 respectively (Table 4).The detection result of quadruplex qPCR is consistent with the uniplex qPCR(P>0.05). The coefficients of variation (CVs) of the five parallel tests for the four types of HPV plasmids were all below 5% (Table 4).
Table 4. Results of replicability test of AllGlo quadruplex qPCR.
Concentration* | HPV6 | HPV11 | HPV16 | HPV18 | ||||
Intra# | Inter | Intra | Inter | Intra | Inter | Intra | Inter | |
102 | <1.1 | 1.43 | <1.16 | 0.90 | <1.31 | 1.00 | <1.39 | 1.02 |
104 | <0.86 | 0.78 | <1.25 | 0.95 | <1.27 | 0.96 | <1.46 | 1.23 |
106 | <1.21 | 0.80 | <1.07 | 0.79 | <1.21 | 0.99 | <1.26 | 0.86 |
108 | <1.17 | 0.97 | <0.92 | 0.72 | <1.96 | 1.12 | <1.16 | 0.95 |
Five side-by-side AllGlo quadruplex quantitative PCR assay were carried out using the DNA aliquots in triplicate to determine the mean CT value, and the mean CT value was used for statistics of coefficient of variation (%) for four HPV types.
copies/test.
Intra-assay coefficient variation.
Inter-assay coefficient variation.
Preparation of a Standard Curve
Five concentrations of plasmids of each type (103, 104, 105, 106, and 107 copies/test) were used to construct a standard curve with the AllGlo quadruplex fluorescence quantitative PCR system. The mean amplification efficiencies for HPV 6, 11, 16, and 18 were 0.97, 1.10, 0.93 and 1.20, respectively, and the mean correlation coefficient (r2) of each standard curve was above 0.99.
Results of Clinical Specimens Detection
The results obtained with AllGlo quadruplex fluorescence qPCR, HPV GA test and TaqMan uniplex qPCR method were summarized in Table 2.The agreement rate between AllGlo quadruplex fluorescence qPCR, HPV GA test and TaqMan uniplex qPCR was 100%. Single-tube AllGlo probe quadruplex fluorescence qPCR could simultaneously type HPV 6, 11, 16, and 18 and quantitatively detect the viral load of each HPV at the same time. The detection sensitivity of AllGlo probe quadruplex fluorescence qPCR was higher than that of HPV GA test and TaqMan uniplex qPCR.
Discussion
The fluorescence PCR technique is becoming increasingly important in the diagnosis of human diseases, such as influenza virus, avian flu virus [30,31], cytomegalovirus (CMV) [32], and severe acute respiratory syndrome (SARS) virus [33]. Fluorescence PCR has advantages over conventional PCR [34,35].The former generates an amplification kinetics curve, which directly reflects the dynamic changes of the PCR process in real time. With the development of molecular biology and molecular marker techniques, multiplex fluorescence quantitative PCR technology is becoming more widely used. Multiplex PCR not only significantly reduces the workload but also increases the accuracy and comparability of the experiment. Methodologically, the multiplex fluorescence quantitative PCR technique is also suitable for HPV viral load and genotyping detection, especially for detecting a large number of samples simultaneously.
Quantitative PCR has been developed based on conventional PCR techniques. The quantitation of DNA or RNA templates is achieved by determining how many cycles are needed to reach a certain level of fluorescence. Currently used probes in fluorescence PCR include TaqMan probes, FRET probes, molecular signal probes, new fluorescent double-stranded replacement probes [36,37] and AllGlo probes. FRET probes are not commonly used in real-time monitoring but are used in melting-point analysis and genotyping after the completion of PCR amplification [38]. It is difficult to achieve the specificity in genotyping with conventional TaqMan probes; MGB was reported to enhance the specificity. However, MGB increases the cost and the difficulties in probe design and synthesis [39]. Molecular signal probes have complicated designs when used in genotyping, and they are also inefficient in single-base discrimination [40]. Currently, the most widely used probe in the clinical laboratory is TaqMan. However, it is difficult to design TaqMan experiments to detect multiple targets simultaneously, and this seriously limits the application of real-time PCR in genotyping [41,42].
The AllGlo probe is the latest generation of quantitative fluorescent probes invented by AlleLogic Biosciences Corporation. AllGlo probes use two identical fluorophores that are specially selected in such a way that the two fluorophores are mutually quenched when both are conjugated to the probe oligonucleotide. Both fluorophores become dequenched when the probe is cleaved. This study, the AllGlo probe quadruplex quantitative PCR was performed to simultaneously detect and differentiate human papillomavirus genotypes 6, 11, 16 and 18. Samples of four types of HPV (HPV 6, 11, 16, and 18) were PCR-amplified and sequence-confirmed in order to ensure the reliability of the fluorescence qPCR. Plasmids containing the target gene were cloned by T-A cloning for the preparation of standard DNA stock. By optimizing the concentrations and combinations of primers and probes in AllGlo quadruplex quantitative PCR, we finally resolved the issue of mutual interference among primers in multiplex PCR and established a single-tube quadruplex fluorescence quantitative PCR technique based on the AllGlo probe. This new approach allows simultaneous detection and typing of four HPV types in a single tube. The r2 values of all of the standard curves were larger than 0.99, and the amplification efficiency was between 0.91 and 1.23, which meets the requirement for fluorescence quantitative PCR standard curves [43,44]. The agreement rate between AllGlo quadruplex fluorescence qPCR, HPV GA test and TaqMan uniplex qPCR was 100%. Single-tube AllGlo probe quadruplex fluorescence qPCR could simultaneously type HPV 6, 11, 16, and 18 and quantitatively detect the viral load of each HPV at the same time. Compared with the HPV GA test and TaqMan uniplex qPCR method, the AllGlo quadruplex qPCR method enjoys a high sensitivity and a wide linear range. In our experiment, the sensitivity of quadruplex fluorescence quantitative PCR can reach 10 to100 copies/test, while the sensitivity of HPV GA test and TaqMan uniplex qPCR method was above 100 copies/test. For the same sample, the positive rate and accuracy of the AllGlo quadruplex qPCR method was higher than those of the HPV GA test and TaqMan uniplex qPCR method. In addition, AllGlo probe quadruplex fluorescence quantitative PCR also has the advantages of relatively high throughput, time savings, simple operation, and lower cost, which are key factors that are needed in order to be qualified for clinical applications. The repeatability, sensitivity and specificity were high enough to be qualified for both qualitative and quantitative detection in clinical settings.
Conclusion
AllGlo quadruplex quantitative PCR has the advantages of relatively high throughput, good reproducibility, high sensitivity, high specificity, and a wide linear range of detection. The convenient single-tube format makes this assay a powerful tool for the study of mixed infections caused by multiple pathogens, viral typing and viral load quantification,meanwhile, this method could be used in single nucleotide polymorphism (SNP) and mutation analysis, prenatal diagnosis and genetic disease screening, drug efficacy analysis, tumor gene expression detection, and so on. The assay will facilitate molecular epidemiological studies and drug development.
Supporting Information
Funding Statement
The work was supported by the Major National S&T Projects for Infectious Diseases (2008ZX10002-007), the Zhejiang Provincial Natural Science Foundation of China under Grant No.Y2101267 and Bureau of Science and Technology of Hangzhou Grants 20070733B02. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
References
- 1. Ursu RG, Onofriescu M, Nemescu D, Iancu LS (2011) HPV prevalence and type distribution in women with or without cervical lesions in the Northeast region of Romania.Virol J. 8: 558. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Wiley DJ, Douglas J, Beutner K, Cox T, Fife K, et al.. (2002)External genital warts: diagnosis, treatment, and prevention. Clin Infect Dis (Suppl 2): S210–224. [DOI] [PubMed]
- 3. Einstein MH, Baron M, Levin MJ, Chatterjee A, Fox B, et al. (2011) Comparison of the immunogenicity of the human papillomavirus (HPV)-16/18 vaccine and the HPV-6/11/16/18 vaccine for oncogenic non-vaccine types HPV-31 and HPV-45 in healthy women aged 18–45 years. Hum Vaccin12: 1359–1373. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Hong JH, Song SH, Kim JK, Han JH, Lee JK (2009) Comparison of the novel human papillomavirus 4 auto-capillary electrophoresis test with the hybrid capture 2 assay and with the PCR HPV typing set test in the detection of high-risk HPV including HPV 16 and 18 genotypes in cervical specimens. J Korean Med Sci 4: 579–584. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Hiller T, Poppelreuther S, Stubenrauch F, Iftner T (2006) Comparative analysis of 19 genital human papillomavirus types with regard to p53 degradation, immortalization, phylogeny, and epidemiologic risk classification. Cancer Epidemiol Biomarkers Prev 15: 1262–1267. [DOI] [PubMed] [Google Scholar]
- 6. Sahasrabuddhe VV, Luhn P, Wentzensen N (2011) Human papillomavirus and cervical cancer: biomarkers for improved prevention efforts. Future Microbiol. 6: 1083–1098. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Chuang LC, Hu CY, Chen HC, Lin PJ, Lee B, et al. (2012) Associations of human leukocyte antigen class II genotypes with human papillomavirus 18 infection and cervical intraepithelial neoplasia risk. Cancer 118: 223–231. [DOI] [PubMed] [Google Scholar]
- 8. Jong E, van Gorp EC, Mulder JW, Tol A, Smits PH (2009) Effect of HIV viral load, CD4 cell count and antiretroviral therapy on human papillomavirus prevalence in urine samples of HIV-infected men. Int J STD AIDS 20: 262–264. [DOI] [PubMed] [Google Scholar]
- 9. Fontaine J, Hankins C, Money D, Rachlis A, Pourreaux K, et al. (2008) Human papillomavirus type 16 (HPV-16) viral load and persistence of HPV-16 infection in women infected or at risk for HIV. J Clin Virol 43: 307–312. [DOI] [PubMed] [Google Scholar]
- 10. Palefsky JM, Giuliano AR, Goldstone S, Moreira ED Jr, Aranda C, et al. (2011) HPV vaccine against anal HPV infection and anal intraepithelial neoplasia. N Engl J Med 365: 1576–1585. [DOI] [PubMed] [Google Scholar]
- 11. Dunne EF, Sternberg M, Markowitz LE, McQuillan G, Swan D, et al. (2011) Human papillomavirus (HPV) 6, 11, 16, and 18 prevalence among females in the United States–National Health And Nutrition Examination Survey, 2003–2006: opportunity to measure HPV vaccine impact? J Infect Dis 204: 562–565. [DOI] [PubMed] [Google Scholar]
- 12. Castellsague X, Munoz N, Pitisuttithum P, Ferris D, Monsonego J, et al. (2011) End-of-study safety, immunogenicity, and efficacy of quadrivalent HPV (types 6, 11, 16, 18) recombinant vaccine in adult women 24–45 years of age. Br J Cancer 105: 28–37. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Neuzil KM, Canh do G, Thiem VD, Janmohamed A, Huong VM, et al. (2011) Immunogenicity and reactogenicity of alternative schedules of HPV vaccine in Vietnam: a cluster randomized noninferiority trial. JAMA 305: 1424–1431. [DOI] [PubMed] [Google Scholar]
- 14. Giuliano AR, Palefsky JM, Goldstone S, Moreira ED Jr, Penny ME, et al. (2011) Efficacy of quadrivalent HPV vaccine against HPV Infection and disease in males. N Engl J Med 364: 401–411. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Muñoz N, Kjaer SK, Sigurdsson K, Iversen OE, Hernandez-Avila M, et al. (2010) Impact of human papillomavirus (HPV)-6/11/16/18 vaccine on all HPV-associated genital diseases in young women. J Natl Cancer Inst 102: 325–339. [DOI] [PubMed] [Google Scholar]
- 16. Lenselink CH, Melchers WJ, Quint WG, Hoebers AM, Hendriks JC, et al. (2008) Sexual behaviour and HPV infections in 18 to 29 year old women in the pre-vaccine era in the Netherlands. PLoS One 3: e3743. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Shen-Gunther J, Yu X (2011) HPV molecular assays: defining analytical and clinical performance characteristics for cervical cytology specimens. Gynecol Oncol 123: 263–271. [DOI] [PubMed] [Google Scholar]
- 18. Tinelli A, Leo G, Dell’Edera D, Storelli F, Galante MM, et al. (2011) Molecular methods for a correct diagnosis of multiple HPV infections and clinical implications for vaccine. Int J Gynecol Cancer 21: 545–550. [DOI] [PubMed] [Google Scholar]
- 19. Vince A, Lepej SZ (2010) Diagnostic methods and techniques in cervical cancer prevention Part II: Molecular diagnostics of HPV infection. Med Glas Ljek komore Zenicko-doboj kantona 7: 18–25. [PubMed] [Google Scholar]
- 20. Khair MM, Mzibri ME, Mhand RA, Benider A, Benchekroun N, et al. (2009) Molecular detection and genotyping of human papillomavirus in cervical carcinoma biopsies in an area of high incidence of cancer from Moroccan women. J Med Virol 81: 678–684. [DOI] [PubMed] [Google Scholar]
- 21. Han J, Swan DC, Smith SJ, Lum SH, Sefers SE, et al. (2006) Simultaneous amplification and identification of 25 human papillomavirus types with Templex technology. J Clin Microbiol 44: 4157–4162. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Tang J, Zhou L, Duan LL, Cao X, Wang Y (2011) Development and evaluation of a new detection tool-visual DNA microarray for simultaneous and specific detection of human immunodeficiency virus type-1 and hepatitis C virus. Mol Biol Rep38: 5341–5348. [DOI] [PubMed] [Google Scholar]
- 23.Chen MY, Sun LD, Zhao J, Zeng K (2009)Multiplex fluorescent quantitative PCR for detecting deep fungal infection in patients with systemic lupus erythematosus. Nan Fang Yi Ke Da Xue Xue Bao 29: 2112–2114, 2121. [PubMed]
- 24. Lassauniere R, Kresfelder T, Venter M (2010) A novel multiplex real-time RT-PCR assay with FRET hybridization probes for the detection and quantitation of 13 respiratory viruses. J Virol Methods 165: 254–260. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25. Kalogianni DP, Elenis DS, Christopoulos TK, Ioannou PC (2007) Multiplex quantitative competitive polymerase chain reaction based on a multianalyte hybridization assay performed on spectrally encoded microspheres. Anal Chem 79: 6655–6661. [DOI] [PubMed] [Google Scholar]
- 26. Schmitz M, Scheungraber C, Herrmann J, Teller K, Gajda M, et al. (2009) Quantitative multiplex PCR assay for the detection of the seven clinically most relevant high-risk HPV types. J Clin Virol 44: 302–307. [DOI] [PubMed] [Google Scholar]
- 27.Dupont M, Goldsborough A, Levayer T, Savare J, Rey JM, et al.. (2002)Multiplex fluorescent RT-PCR to quantify leukemic fusion transcripts. Biotechniques 33: 158–160, 162, 164. [DOI] [PubMed]
- 28. Takács T, Jeney C, Kovács L, Mózes J, Benczik M, et al. (2008) Molecular beacon-based real-time PCR method for detection of 15 high-risk and 5 low-risk HPV types. J Virol Methods 149: 153–162. [DOI] [PubMed] [Google Scholar]
- 29. O’Regan E, McCabe E, Burgess C, McGuinness S, Barry T, et al. (2008) Development of a real-time multiplex PCR assay for the detection of multiple Salmonella serotypes in chicken samples. BMC Microbiol 8: 156. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. De Santis R, Faggioni G, Ciammaruconi A, Fillo S, Clausi V, et al. (2010) A FRET based melting curve analysis to detect nucleotide variations in HA receptor-binding site of H5N1 virus. Mol Cell Probes 24: 298–302. [DOI] [PubMed] [Google Scholar]
- 31. Wang W, Ren P, Mardi S, Hou L, Tsai C, et al. (2009) Design of multiplexed detection assays for identification of avian influenza a virus subtypes pathogenic to humans by SmartCycler real-time reverse transcription-PCR. J Clin Microbiol. 47: 86–92. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32. Hänfler J, Kreuzer KA, Laurisch K, Rayes N, Neuhaus P, et al. (2003) Quantitation of cytomegalovirus (hCMV) DNA and beta-actin DNA by duplex real-time fluorescence PCR in solid organ (liver) transplant recipients. Med Microbiol Immunol 192: 197–204. [DOI] [PubMed] [Google Scholar]
- 33. Ksiazek TG, Erdman D, Goldsmith CS, Zaki SR, Peret T, et al. (2003) A novel coronavirus associated with severe acute respiratory syndrome. N Engl J Med 348: 1953–1966. [DOI] [PubMed] [Google Scholar]
- 34. Wacharapluesadee S, Hemachudha T (2010) Ante- and post-mortem diagnosis of rabies using nucleic acid-amplification tests. Expert Rev Mol Diagn 10: 207–218. [DOI] [PubMed] [Google Scholar]
- 35. Xie Z, Xie L, Pang Y, Lu Z, Xie Z, et al. (2008) Development of a real-time multiplex PCR assay for detection of viral pathogens of penaeid shrimp. Arch Virol 153: 2245–2251. [DOI] [PubMed] [Google Scholar]
- 36. Kutyavin IV (2010) New approach to real-time nucleic acids detection: folding polymerase chain reaction amplicons into a secondary structure to improve cleavage of Forster resonance energy transfer probes in 5'-nuclease assays. Nucleic Acids Res 38: e29. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37. Li H, Franzini RM, Bruner C, Kool ET (2010) Templated chemistry for sequence-specific fluorogenic detection of duplex DNA. Chembiochem 11: 2132–2137. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38. Girkin JM, Mohammed MI, Ellis EM (2011) A miniaturised integrated biophotonic point-of-care genotyping system. Faraday Discuss 149: 115–123. [DOI] [PubMed] [Google Scholar]
- 39. Samson MC, Gullì M, Marmiroli N (2010) Quantitative detection method for Roundup Ready soybean in food using duplex real-time PCR MGB chemistry. J Sci Food Agric 90: 1437–1444. [DOI] [PubMed] [Google Scholar]
- 40. Jenison R, La H, Haeberli A, Ostroff R, Polisky B (2001) Silicon-based biosensors for rapid detection of protein or nucleic acid targets. Clin Chem 47: 1894–1900. [PubMed] [Google Scholar]
- 41. Li P, Ruel T, Fujimoto K, Hatano H, Yukl S, et al. (2010) Novel application of Locked Nucleic Acid chemistry for a Taqman assay for measuring diverse human immunodeficiency virus type 1 subtypes. J Virol Methods 170: 115–120. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42. Balamurugan V, Sen A, Venkatesan G, Yadav V, Bhanot V, et al. (2010) Application of semi-quantitative M gene-based hydrolysis probe (TaqMan) real-time RT-PCR assay for the detection of peste des petits ruminants virus in the clinical samples for investigation into clinical prevalence of disease. Transbound Emerg Dis 57: 383–395. [DOI] [PubMed] [Google Scholar]
- 43. Swillens S, Dessars B, Housni HE (2008) Revisiting the sigmoidal curve fitting applied to quantitative real-time PCR data. Anal Biochem 373: 370–376. [DOI] [PubMed] [Google Scholar]
- 44. Garson JA, Huggett JF, Bustin SA, Pfaffl MW, Benes V, et al. (2009) Unreliable real-time PCR analysis of human endogenous retrovirus-W (HERV-W) RNA expression and DNA copy number in multiple sclerosis. AIDS Res Hum Retroviruses 25: 377–378. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.