Table 3. RT-PCR/ESI-MS assay data versus historical sequencing data.

Comparison of early and late RT-PCR/ESI-MS data and NCBI data.

Sample
Size
Number of
Unique
Genotypes
Discovered
Number(Percent)
of Samples with
Sequence Variation
(SNPs)
Average number
of SNPs per
Sample
Early pH1N1 samples
analyzed by RT-
PCR/ESI-MS
190 8 20 (10.5%) 0.105
Early pH1N1 samples
sequenced by NCBI
760 27 102 (13.4%) 0.139
Late pH1N1 samples
analyzed by RT-
PCR/ESI-MS
69 12 48 (69.6%) 0.855
Late pH1N1 samples
sequenced by NCBI
770 73 348 (45.2%) 0.587