. 2012 Dec;19(6):315–323. doi: 10.3747/co.19.1173

TABLE I.

Accuracy of her2 testing with chromogenic in situ hybridization using liquid-based cytology samples taken from breast tumours

Reference
Sumiyoshi et al., 200616 Sartelet et al., 200517 Vocaturo et al., 200618 Almeida and Correia, 200819
Samples (n) 58 103 53 36
Fixative 95% Ethanol ThinPrepa ThinPrepa Not specified
Ethanolb
Antibody A0485 NCL-CB11c A0485 A0485
HercepTestd HercepTestd HercepTestd
Sensitivity [% (95% ci)]e 84.00 100 85 (73 to 95)
Specificity [% (95% ci)]e 87.90 96% (92.0 to 99.9) 100 Concordance rate 94% (cytology samples vs. histology samples)
Predictive value [% (95% ci)]
  Positive 86.40 100 (79 to 93)
  Negative 100 92 (86 to 98)
Accuracy (%) 86.20
a

Contains methanol (Cytyc, Boxborough, Massachusetts, U.S.A.).

b

Samples were post-fixed in absolute ethanol.

c

Novocastra Laboratories, Newcastle Upon Tyne, U.K.

d

Dake, Glostrup, Denmark.

e

Compared with formalin-fixed, paraffin-embedded tissue sections.