Table 2.

Intra-assay accuracy of real-time PCR for EEHV1, 2, ¾, 5, and 6

Input copies EEHV1 EEHV2 EEHV3/4 EEHV5 EEHV6

Mean±SDa CVb Mean±SDa CVb Mean±SDa CVb Mean±SDa CVb Mean±SDa CVb

10 35.51±0.43 1.23 34.66±0.66 1.92 32.02±0.60 1.87 31.38±0.37 1.18 34.40±0.62 1.79
102 32.37±0.22 0.67 31.53±0.12 0.37 28.60±0.13 0.46 28.35±0.11 0.37 30.83±0.09 0.30
103 28.86±0.06 0.21 28.25±0.18 0.62 25.27±0.10 0.40 24.89±0.07 0.29 27.55±0.09 0.33
104 25.47±0.04 0.14 24.72±0.03 0.14 21.86±0.04 0.17 21.49±0.13 0.61 24.12±0.09 0.37
105 22.10±0.04 0.18 21.35±0.04 0.20 18.62±0.07 0.37 18.09±0.14 0.76 20.87±0.04 0.18
a

Mean and standard deviation of the threshold cycle (Cq) from 5 replicates

b

Coefficient of variation