Table 2.
Intra-assay accuracy of real-time PCR for EEHV1, 2, ¾, 5, and 6
Input copies | EEHV1 | EEHV2 | EEHV3/4 | EEHV5 | EEHV6 | |||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
Mean±SDa | CVb | Mean±SDa | CVb | Mean±SDa | CVb | Mean±SDa | CVb | Mean±SDa | CVb | |
| ||||||||||
10 | 35.51±0.43 | 1.23 | 34.66±0.66 | 1.92 | 32.02±0.60 | 1.87 | 31.38±0.37 | 1.18 | 34.40±0.62 | 1.79 |
102 | 32.37±0.22 | 0.67 | 31.53±0.12 | 0.37 | 28.60±0.13 | 0.46 | 28.35±0.11 | 0.37 | 30.83±0.09 | 0.30 |
103 | 28.86±0.06 | 0.21 | 28.25±0.18 | 0.62 | 25.27±0.10 | 0.40 | 24.89±0.07 | 0.29 | 27.55±0.09 | 0.33 |
104 | 25.47±0.04 | 0.14 | 24.72±0.03 | 0.14 | 21.86±0.04 | 0.17 | 21.49±0.13 | 0.61 | 24.12±0.09 | 0.37 |
105 | 22.10±0.04 | 0.18 | 21.35±0.04 | 0.20 | 18.62±0.07 | 0.37 | 18.09±0.14 | 0.76 | 20.87±0.04 | 0.18 |
Mean and standard deviation of the threshold cycle (Cq) from 5 replicates
Coefficient of variation