Table 3.

Reproducibility of real-time PCR for EEHV1, 2, ¾, 5, and 6

Input copies EEHV1 EEHV2 EEHV3/4 EEHV5 EEHV6
Mean±SDa CVb Mean±SDa CVb Mean±SDa CVb Mean±SDa CVb Mean±SDa CVb
10 34.43±0.14 0.40 34.73±0.81 2.34 31.77±0.26 0.81 30.90±0.19 0.60 34.71±0.36 1.02
102 31.16±0.30 0.96 31.50±0.16 0.51 28.66±0.08 0.27 28.02±0.15 0.53 31.05±0.39 1.26
103 27.67±0.26 0.93 28.34±0.45 1.58 25.39±0.15 0.61 24.67±0.07 0.27 27.71±0.34 1.21
104 24.22±0.21 0.88 24.74±0.09 0.38 22.03±0.16 0.73 21.26±0.04 0.18 24.28±0.36 1.49
105 21.52±0.19 0.87 21.39±0.09 0.40 18.68±0.14 0.74 17.82±0.03 0.19 20.85±0.16 0.80
a

Mean and standard deviation of the threshold cycle (Cq) from 5 independent experiments carried out between 1–3 months.

b

Coefficient of variation