Skip to main content
. Author manuscript; available in PMC: 2012 Dec 4.
Published in final edited form as: Phys Med Biol. 2011 Aug 16;56(18):5771–5788. doi: 10.1088/0031-9155/56/18/001

Table 2.

Measurements of Volume, SUVmean and SUVmax evolution, computed with the adaptive threshold and the ASEM methods for each patients.

Patient Method ΔSUVmean (%) ΔV (%) ΔSUVmax without PVC (%) ΔSUVmax with PVC (%)
1 Tb 1 −35.7 −79.8 −51.7 −35.8
Tb 2 −33.5 −83.2
ASEM −33.1 −80.4
2 Tb 1 −69.5 −86.3 −74.2 −76.9
Tb 2 −74.2 −64.9
ASEM −71.4 −65.2
3 Tb 1 −59.7 −81.4 −60.2 −66.9
Tb 2 −68.9 −40.0
ASEM −62.7 −59.5
4 Tb 1 −27.0 −66.1 −32.7 −25.7
Tb 2 −24.2 −71.7
ASEM −26.7 −59.2
5 Tb 1 −28.4 −41.1 −28.1 −42.2
Tb 2 −35.2 −12.9
ASEM −20.6 −52.5
6 Tb 1 −87.3 402.5 −56.1 −87.8
Tb 2 −85.7 74.1
ASEM −83.3 −81.9
7 Tb 1 −65.9 361.0 −58.8 −66.9
Tb 2 −60.7 −16.1
ASEM −47.9 −59.8