Table 2. Estimated percentages of the proportion of tissue irradiated based on the volume of that tissue in the image field.

30 cm FOV 23 cm FOV 15 cm FOV, parotid 15 cm FOV, submandibular Plain radiography, parotid Plain radiography, submandibular
Thyroid 100 80 20 100 100 100
Oesophagus 10 5 2.5 10 10 10
Bone surface 16.5 11 8.25 4.5 11 4.5
Bone marrow 16.5 11 8.25 4.5 11 4.5
Salivary gland 100 100 100 100 100 100
Skin 5 3 2.5 2.5 3 2.5
Brain 100 50 10 5 50 10
Remainder 20 15 10 10 15 10