Table 1.
Cochlear implant processor and programming parameters for each visit on the specific ear.
Subject ID | Test Condition | Processor | Strategy; # of Channels |
Rate (pps) | Ear |
---|---|---|---|---|---|
Visit 1: CI-ONLY | Cochlear Freedom | ACE; 24 | 900 Hz | Right | |
C53B | Visit 2: (1st implant) | Cochlear Freedom | ACE; 24 | 900 Hz | Right |
Visit 2: (2nd implant) | Cochlear Freedom | ACE; 24 | 900 Hz | Left | |
Visit 1: CI-ONLY | Cochlear Freedom | ACE; 24 | 900 Hz | Right | |
C41B | Visit 2: (1st implant) | Cochlear Freedom | ACE; 24 | 900 Hz | Right |
Visit 2: (2nd implant) | Cochlear Freedom | ACE; 24 | 900 Hz | Left | |
Visit 1: CI-ONLY | Med-EL Tempo+ | CIS+; 9 | 1993 Hz | Right | |
M55B | Visit 2: (1st implant) | Med-EL Tempo+ | CIS+; 9 | 1993 Hz | Right |
Visit 2: (2nd implant) | Med-EL Opus II | CIS+; 11 | 580 Hz | Left | |
Visit 1: CI-ONLY | AB Auria | Hi Resolution-Sequential; 11 | 2109 Hz | Left | |
A66B | Visit 2: (1st implant) | AB Harmony | Hi Resolution-Sequential; 11 | 2109 Hz | Left |
Visit 2: (2nd implant) | AB Harmony | Hi Resolution-Sequential; 11 | 2109 Hz | Right | |
Visit 1: CI-ONLY | Med-EL Tempo+ | CIS+; 9 | 1212 Hz | Left | |
M13B | Visit 2: (1st implant) | Med-EL Tempo+ | CIS+; 9 | 1212 Hz | Left |
Visit 2: (2nd implant) | Med-EL Opus II | CIS+; 11 | 565 Hz | Right | |
Visit 1: CI-ONLY | Med-EL Opus II | CIS+; 8 | 2000 Hz | Right | |
M76B | Visit 2: (1st implant) | Med-EL Opus II | CIS+; 8 | 2000 Hz | Right |
Visit 2: (2nd implant) | Med-EL Opus II | CIS+; 12 | 1613 Hz | Left | |
Visit 1: CI-ONLY | Med-EL Tempo+ | CIS+; 12 | 1081 Hz | Left | |
M83B | Visit 2: (1st implant) | Med-EL Tempo+ | CIS+; 12 | 819 Hz | Left |
Visit 2: (2nd implant) | Med-EL Opus II | CIS+; 9 | 673 Hz | Right | |
Visit 1: CI+HA | Nucleus 3G | ACE; 20 | 900 Hz | Right | |
C34B | Visit 2: (1st implant) | Cochlear Freedom | ACE; 20 | 900 Hz | Right |
Visit 2: (2nd implant) | Cochlear Freedom | ACE; 20 | 900 Hz | Left | |
Visit 1: CI+HA | AB Harmony | Fidelity; 9 | 1904 Hz | Right | |
A69B | Visit 2: (1st implant) | AB Harmony | Fidelity; 9 | 1904 Hz | Right |
Visit 2: (2nd implant) | AB Harmony | Fidelity; 13 | 3712 Hz | Left | |
Visit 1: CI-ONLY | Nucleus 3G | ACE; 22 | 1200 Hz | Right | |
C10B | Visit 2: (1st implant) | Cochlear Freedom | ACE; 22 | 1200 Hz | Right |
Visit 2: (2nd implant) | Cochlear Freedom | ACE; 22 | 900 Hz | Left | |
Visit 1: CI+HA | Med-EL Tempo+ | CIS+; 12 | 1363 Hz | Right | |
M53B | Visit 2: (1st implant) | Med-EL Tempo+ | CIS+; 12 | 1363 Hz | Right |
Visit 2: (2nd implant) | Med-EL Opus II | FSP; 12 | 997 Hz | Left | |
Visit 1: CI-ONLY | Med-EL Opus II | FSP; 12 | 1818 Hz | Left | |
M68B | Visit 2: (1st implant) | Med-EL Opus II | FSP; 12 | 1818 Hz | Left |
Visit 2: (2nd implant) | Med-EL Opus II | FSP; 12 | 1961 Hz | Right | |
Visit 1: CI-ONLY | Clarion PSP | CIS; 8 | 812 Hz | Right | |
A32B | Visit 2: (1st implant) | Clarion PSP | CIS; 8 | 812 Hz | Right |
Visit 2: (2nd implant) | AB Harmony | Fidelity; 15 | 3712 Hz | Left |
Visit 1=testing with CI-ONLY or CI+HA. Visit 2=testing with CI+CI.
1st implant=ear implanted first. 2nd implant=ear implanted second.