Assessing mitochondrial respiration in isolated hearts using 17O MRS

Ming Lu a,b, Bharath Atthe a,b, Gheorghe D Mateescu b,c,d, Chris A Flask a,b,c, Xin Yu a,b,c,e,*
PMCID: PMC3522750  NIHMSID: NIHMS426342  PMID: 22161858

Abstract

The application of 17O MRI and MRS for the evaluation of cardiac mitochondrial function has been limited because of the challenge of detecting metabolic H217 in the vast background of naturally abundant H217. In this study, we have developed a direct 17O MRS approach to examine the feasibility and sensitivity of detecting metabolically produced H217 in isolated rat hearts perfused with 17O2-enriched Krebs-Henseleit buffer containing normal (1.5 mM) and high (2.5 mm) calcium (Ca2+) concentrations to induce high workload. Consistent with increased workload at high Ca2+ concentration, the measured myocardial oxygen consumption rate (MVO2) increased by 82%. Dynamic 17O MRS showed an accelerated increase in the H217O signal at high Ca2+ concentration, suggesting increased mitochondrial production of H217O in concordance with the increased workload. A compartment model was developed to describe the kinetics of H217O production as a function of MVO2. The myocardial 17O2 consumption rate (MV17O2) was determined by least-squares fitting of the model to the NMR-measured H217O concentration. Consistent with the measured MVO2, the model-determined MV17O2 showed a 92% increase at high Ca2+ concentration. The increase in metabolic activity at high workload allowed the balance between ATP production and utilization to be maintained, leading to a similar phosphocreatine to ATP ratio. These results demonstrate that dynamic 17O MRS can provide a valuable tool for the detection of an altered metabolic rate associated with a change in cardiac workload.

Keywords: 17O spectroscopy, mitochondrial function, myocardial metabolism, oxygen consumption, energy–function relationship

INTRODUCTION

The heart is the most energy-demanding organ because of its nonstop contraction. There is increasing evidence that abnormal mitochondrial function and energy metabolism are characteristic of several prevalent cardiac diseases, such as heart failure (13), and ischemic and diabetic cardiomyopathy (46). However, our fundamental understanding of cardiac energetics in diseased hearts remains incomplete because of the limited means to investigate myocardial metabolism in intact hearts. To date, most of the studies on mitochondrial function have been performed in isolated mitochondria or with in vitro tissue samples. As a result of the lack of nondestructive methods to quantify mitochondrial respiration in vivo, an integrative understanding of the mechanisms underlying metabolic dysfunction in diseased hearts is still incomplete.

In the last 20 years, MRS has become a valuable tool for the evaluation of cardiac metabolism under various pathophysiological conditions, largely because of its noninvasive nature and the exquisitely detailed information it can offer (7,8). While 13C and 31P MRS allow the quantification of substrate metabolism and ATP synthesis, 17O MRS provides the unique opportunity to evaluate mitochondrial respiration in intact, viable tissues through the observation of metabolic H217O production via the reduction of 17O2. The use of 17O MRS for the assessment of mitochondrial H217O production was first demonstrated, independently, in 1991 by Mateescu et al. (9) in mouse brain and Pekar et al. (10) in cat brain. Recently, 17O MRS methods for the quantification of cerebral oxygen consumption have been developed in animals through the monitoring of dynamic changes of metabolically generated H217O from inhaled 17O2 (1116). However, cardiac applications of 17O MRS have been limited. Only a few studies have explored the potential of detecting mitochondrial function in the heart with 17O MR techniques (1720).

Current in vivo 17O MRS methods are complicated by several factors that can potentially affect the accuracy of the measurement of mitochondrial respiration. These include the efflux of metabolic H217O via normal tissue water exchange and the input of H217O from other metabolizing tissues. These issues can be addressed using an isolated perfused heart model. The advantages of using an isolated heart model are as follows: (i) it allows precise control of the substrates and other experimental conditions; (ii) it enables easy manipulation of mitochondrial respiration via changes in cardiac workload; (iii) it allows the simultaneous recording of cardiac function to investigate the energy–function relationship; and (iv) it eliminates systemic H217O input from other metabolizing organs. Therefore, 17O MRS on isolated perfused hearts provides the opportunity to validate quantitative 17O MRS methods for the accurate assessment of mitochondrial respiration in living tissues. These ex vivo MRS data may serve as the benchmarks for in vivo studies.

In this study, we aimed to develop a 17O MRS method on isolated perfused hearts to examine the feasibility and sensitivity of 17O MRS for the detection of metabolically produced H217O in hearts at different workloads. A closed-loop perfusion system specifically designed for economic and efficient 17O MRS studies was developed. Metabolically produced H217O was detected by rapid, dynamic 17O MRS on a 9.4-T vertical-bore spectrometer. A compartment model that describes the kinetics of H217O production was also developed for the estimation of the myocardial oxygen consumption rate (MVO2). Our results demonstrate that a high-temporal-resolution 17O MRS method provides an opportunity to detect an altered mitochondrial respiration rate associated with a change in cardiac workload.

MATERIALS AND METHODS

Perfusion system

A major challenge in performing 17O MRS experiments on perfused hearts is the large system volume that may reduce the detectability of metabolic H217O because of the dilution of metabolic H217O by natural abundance H217O. To improve the detection sensitivity, we developed a closed-loop perfusion system with a total volume of only 26 mL (Fig. 1A). The perfusion system has two gravitational reservoirs for 17O2- and 16O2-oxygenated perfusate, respectively. The perfusion pressure was maintained at a constant level by adjusting the level of the overflow port in the reservoir. Re-oxygenation of the recycling perfusate was achieved via 17O2-filled silicone tubing inserted into the perfusion line.

Figure 1.

Figure 1

(A) Schematics of the perfusion system. Two gravitational reservoirs with overflow ports supply the heart with 16O2- and 17O2-oxygenated buffer. Re-oxygenation of the buffer during 17O MRS acquisition is accomplished via 17O2-filled silicone tubing embedded in the water-jacketed perfusion column. Pressurized chamber (B) and closed-loop gas-exchange system (C) for efficient oxygenation of the perfusate with 17O2.

Buffer preparation

The formidable cost of 17O2 requires a low-loss system for efficient oxygenation of the perfusate with 17O2. Two approaches were attempted in the current study—a pressurized chamber (Fig. 1B) and a gas-exchange circuit (Fig. 1 C)—with the goal of maximizing 17O2 usage for each experiment. In the gas-exchange system, oxygenation with 17O2 was achieved by circulating the perfusate through a cartridge of 17O2-filled silicone tubing. The high gas permeability of the silicone tubing allowed the efficient transfer of 17O2 to the perfusate. In the second approach, we used a pressurized chamber for buffer oxygenation. On introduction of 17O2 (70% enrichment; Rockland Technimed Ltd., Airmont, NY, USA), the pressure of the chamber was increased to about 8 psi and a magnetic stirrer operating at 700 rpm allowed the gas to quickly dissolve into the perfusate. To maximize the 17O2 content in the perfusate, the perfusate was degassed at atmospheric pressure by bubbling helium gas to reduce the content of 16O2 prior to oxygenation with 17O2.

Perfusion protocol

Isolated hearts from 2-month-old male Sprague-Dawley rats were perfused with oxygenated Krebs-Henseleit buffer containing (in mm): NaCl, 118; NaHCO3, 25; KCl, 5.3; MgSO4, 1.2; CaCl2, 1.5 or 2.5; glucose, 10. Two different calcium (Ca2+) concentrations, normal at 1.5 mm (NCA, n = 7) and high at 2.5 mm (HCA, n = 7), were used to induce normal and high workloads, respectively. The left ventricular developed pressure (LVDP) and heart rate (HR) were measured via a water-filled balloon connected to a pressure transducer (ADInstruments, Colorado Springs, CO, USA). The rate–pressure product (RPP) was used as an index of ventricular workload.

At the start of the perfusion protocol, 16O2-oxygenated perfusate was supplied for 15 min to establish metabolic equilibrium. A 31P spectrum was collected to verify the metabolic status of the heart. A natural abundance 17O spectrum was then collected for background subtraction. The perfusate was then switched to 17O2-oxygenated buffer. Dynamic acquisition of 17O spectra began immediately for 5 min. To reduce the negative inotropic effect caused by adenosine accumulation, theophylline (Sigma-Aldrich, St. Louis, MO, USA), an adenosine antagonist, was infused at 0.5 mL/min once the perfusate was switched to 17O2-oxygenated buffer. At the end of the perfusion protocol, hearts were taken off the perfusion column, blotted dry and weighed.

To validate the 17O MRS results, the oxygen content (pO2)of the perfusion medium in the supply line and in coronary effluent was measured with a blood-gas analyzer (Radiometer ApS, Copenhagen, Denmark). MVO2 was calculated experimentally from the measured coronary flow rate and the difference in pO2 between the perfusate and the coronary effluent (21). These measurements were performed during the acquisition of the 31P spectrum. All procedures were approved by the Institutional Animal Care and Use Committee at Case Western Reserve University.

31P and dynamic 17O MRS

31P and 17O MR spectra were acquired on a Bruker AVANCE-400 9.4-T vertical-bore spectrometer (Bruker Biospin Co., Billerica, MA, USA) with a 20-mm broad-band probe. Field homogeneity was adjusted by shimming on the proton signal to a linewidth of 30–50 Hz. 31P spectra were acquired at 162 MHz with 90° radiofrequency pulses, TR = 1.3 s, 12 K dataset and 64 averages. Spectrum analysis was performed using NMR-dedicated software MestRec (Mestrelab Research SL, Santiago de Compostela, Spain). Raw free induction decay signals were converted into frequency domain spectra by Fourier transformation following the application of an exponential filter (15-Hz line broadening) to enhance the signal-to-noise ratio. Relative ATP and phosphocreatine (PCr) levels were quantified by fitting the β-ATP and PCr peaks with Lorentzian curves, respectively, followed by the integration of these two peak areas. The PCr to ATP ratio was calculated as an index of the high energetic status of the heart.

Sequential 17O spectra were acquired at 54 MHz with 90° radiofrequency pulses, TR = 300 ms, 1 K dataset and 64 averages. The temporal resolution for 17O acquisition was 20 s. For spectrum quantification, the natural abundance 17O signal was digitally subtracted. The raw MRS signal was processed by exponential filtering with a line broadening of 30 Hz, followed by Fourier transformation to obtain frequency domain spectra. H217O was quantified by fitting the resonance peaks with Lorentzian curves, followed by the integration of the peak area. Assuming an average water concentration of 55 M in the whole NMR tube, the H217O concentration was calculated using the natural abundance 17O spectrum as the reference.

Kinetic analysis

To quantify the mitochondrial respiration rate from 17O MRS data, we developed a compartment model to describe the transport and production of metabolic H217O during the perfusion protocol. The model included three compartments: the heart; the fluid in the NMR tube that surrounded the heart; and the recirculating perfusate (Fig. 2).

Figure 2.

Figure 2

Three-compartment model of H217O generation and recirculation for the estimation of mitochondrial respiration from 17O MRS data. FL, coronary flow rate; HW, wet heart weight.

According to the mass balance principle, the H217O content in the heart (Ch; μmol/g wet weight) is governed by:

HWdChdt=2MV17O2HW+FLCrFLChp [1]

where HW is the wet heart weight (g), MV17O2 is the myocardial 17O2 consumption rate (μmol/min/g wet weight), FL is the coronary flow rate (mL/min) measured during the experiment, Cr is the H217O concentration in the recirculating perfusate (μmol/mL) and p is the myocardium–blood partition coefficient of water. A myocardium–blood partition coefficient of 0.91 mL/g wet weight was used in the current study (22).

The mass balance of the H217O content in the NMR tube (Ct; μmol/mL) can be described as:

VtdCtdt=FL(ChpCt) [2]

where Vt is the fluid volume in the NMR tube. Vt was maintained at 6 mL in the current study.

Similarly, the change in H217O content in the recirculating perfusate (Cr; μmol/mL) can be described as:

VrdCrdt=FL(CtCr) [3]

where Vr is the volume of the circulating perfusate. The initial perfusate volume, including both the reservoir and the tubing, was 20 mL. With the infusion of theophylline at 0.5 mL/min, the total recirculating perfusate (Vr) can be described by the following equation:

Vr=20+0.5t

The model output was the NMR signal arising from both the heart and the fluid in the NMR tube, i.e.:

SNMR=HWCh+VtCt [4]

The only unknown parameter in Equations [13] is the myocardial 17O2 consumption rate (MV17O2), which was determined from the least-squares fitting of the model output (Equation [4]) to the NMR-measured metabolic H217O accumulation.

Statistical analysis

All data are presented as means±standard deviation. Comparisons of datasets were performed using unpaired Student's t-test. Differences in mean values were considered to be significant at a probability level of <5%.

RESULTS

Perfusate oxygenation with 17O2 gas

Both the closed-loop system and the pressurized chamber allowed efficient oxygenation of the buffer with 17O2 gas. With the closed-loop system, the pO2 of 40 mL of perfusate was increased to >400 mmHg within 2 min of circulation and at the cost of only 30 mL of 17O2 gas. The efficiency of the pressurized chamber was slightly higher, with the pO2 of 50 mL of perfusate increased to >500 mmHg within 2 min and at the cost of 30 mL of 17O2 gas.

Contractile function

The body weight and heart weight were similar between the two experimental groups. The average heart weights were 1.71±0.27 g and 1.91±0.14 g for the NCA and HCA groups, respectively (p = not significant). The average HR was also similar between the two groups: 339±43 beats/min for the NCA group and 321±24 beats/min for the HCA group (p = not significant). The HR remained constant during data acquisition (Fig. 3A).

Figure 3.

Figure 3

Contractile function during 17O2-enriched buffer perfusion. (A) Heart rate. (B) Left ventricular developed pressure (LVDP). (C) Rate–pressure product (RPP). *p<0.05. HCA, high calcium concentration group; NCA, normal calcium concentration group.

LVDP decreased slightly from 59±24 mmHg at the beginning of 17O perfusion to 48±23 mmHg at the end of 5 min of 17O MRS data acquisition in the NCA group. This reduction in LVDP was even more pronounced in the HCA group: from 92±25 mmHg to 59±26 mmHg (Fig. 3B). As a result, RPP changed from 16 800±5900 mmHg/min to 14 300±5400 mmHg/min for the NCA group, and from 28 200±9400 mmHg/min to 19 400±8700 mmHg/min for the HCA group (Fig. 3 C). LVDP and RPP were statistically higher in the HCA group for the first 2 min of 17O MRS data acquisition.

31P MRS and measured oxygen consumption rate

A representative 31P spectrum is shown in Fig. 4A. Both groups showed normal and similar PCr to ATP ratios: 1.49±0.16 for the NCA group and 1.45±0.20 for the HCA group (Fig. 4B, p = not significant). The measured MVO2 in the HCA group (6.23±0.19 μmol/min/g wet weight) increased by 82% relative to that of the NCA group (3.42±0.50 μmol/min/g wet weight; p < 0.05; Fig. 4 C).

Figure 4.

Figure 4

(A) Representative 31P NMR spectrum. (B) Phosphocreatine (PCr) to ATP ratio. (C) Measured oxygen consumption rate (MVO2). HCA, high calcium concentration group; NCA, normal calcium concentration group.

Dynamic 17O MRS and model-fitted 17O2 consumption rate

Representative dynamic 17O spectra are shown in Fig. 5A. Both groups showed a progressive increase in the H217O resonance peak (Fig. 5B), suggesting steady production of mitochondrial H217O. As shown in Fig. 5B, hearts perfused with higher Ca2+ concentration demonstrated an accelerated increase in the H217O signal.

Figure 5.

Figure 5

Production of mitochondrial H217O measured by 17O MRS. (A) Representative dynamic 17O spectra. (B) Average time course of H217O accumulation and results of kinetic analysis. HCA, high calcium concentration group; NCA, normal calcium concentration group.

Model-fitted H217O curves are also shown in Fig. 5B. The myocardial 17O2 consumption rate (MV17O2), determined from the least-squares fitting of the model to group-averaged MRS data, increased from 1.15 μmol/min/g wet weight in the NCA group to 2.21 μmol/min/g wet weight in the HCA group, a 92% increase, which is comparable with the overall increase in MVO2 (82%).

DISCUSSION

Oxygen utilization in the mitochondrial respiratory chain is an important index of cardiac metabolic status. Although 15O positron emission tomography (PET) has been the standard imaging modality for the assessment of oxygen consumption for more than 20 years, its application has been limited (23). In 15O PET, all 15O-labeled oxygen contributes to the measured signal, regardless of its chemical form. Hence, data interpretation is complicated, and requires complex compartmental modeling to determine the oxygen consumption rate. Frequently, a multitracer study is necessary to account for blood volume and blood flow in modeling (22). By contrast, 17O MRS provides specificity by measuring only nascent mitochondrial H217O generated from the reduction of 17O2. Therefore, it allows more direct and straightforward quantification of the mitochondrial respiration rate.

Previously, in vivo cardiac 17O MRS/I studies have been reported which used either 17O spectroscopic imaging for the direct detection of H217O (19), or indirect H217O detection via T2 or T imaging (17,20). These studies demonstrated the feasibility of 17O MRS/I for the quantification of the oxygen consumption rate in the heart. Here, we report the first 17O MRS study on isolated perfused hearts. The use of an isolated perfused heart model eliminates the complications arising from the systemic circulation. It also allows better control of the physiological conditions and cardiac function. Such simplification can provide valuable benchmarks for future in vivo development.

Oxygen demand in the heart is primarily governed by its energy expenditure, i.e. workload. In the current study, the cardiac workload was altered by changing the Ca2+ concentration in the perfusate. A higher Ca2+ level caused a higher Ca2+ influx during contraction, leading to increased contractile force, but similar HR (Fig. 3). As a result, RPP was increased significantly in the HCA group. This increase in cardiac workload must be fueled by a corresponding increase in ATP generation. The 17O MRS-observed increase in the kinetics of H217O generation reflected an increase in the mitochondrial respiration rate (Fig. 5), which is coupled to ATP synthesis under normal physiological conditions. In addition, the increase in the measured oxygen consumption rate provides further evidence of increased mitochondrial respiration (Fig. 4). This increase in metabolic activity allowed the balance between ATP production and utilization to be maintained, as demonstrated by the 31P MRS data (Fig.4).

Several studies have reported a linear relationship between oxygen consumption and workload (RPP) both in vivo and ex vivo (24,25). In the current study, the ratios of oxygen consumption between normal- and high-workload hearts were 1.82 and 1.92, measured by the analytical method and by 17O MRS, respectively. The ratio of RPP between the two groups was 1.68 at the beginning of 17O MRS acquisition and decreased to 1.35 towards the end. These results were similar to those reported by Yamamoto et al.(24) in an in vivo PET 15O study on dogs. The authors reported ratios of 2.10 and 2.27 between isoproterenol-stimulated and baseline workload for RPP and MVO2, respectively. The decrease in RPP ratio at the end of 17O MRS acquisition may be caused by reduced metabolic efficiency because of insufficient re-oxygenation.

A major challenge in performing 17O MRS studies in isolated hearts is the dilution of mitochondrial H217O, in combination with the low sensitivity of 17O MRS. This problem is less pronounced for in vivo studies as the total blood volume of a rat is less than 30 mL (26). In addition, the recirculation of metabolic H217O generated in other organs also contributes to the increase in 17O signal acquired from the heart. By contrast, a perfusion system designed for MRS studies typically has a perfusion volume of more than 1 L. The large system volume can quickly dilute the nascent H217O generated in the mitochondria, rendering the signal increase undetectable. To improve the detection sensitivity, we switched to a smaller system volume of only 26 mL on introduction of 17O-oxygenated perfusate. As a result, there were elevated levels of metabolic byproducts which may have an impact on the myocardial contractility. Among these metabolic byproducts is adenosine, which is a potent agent that produces a negative inotropic effect in both atrial and ventricular myocardium. To counteract the adenosine effect, theophylline, an adenosine antagonist, was employed to maintain normal ventricular function (27). Although there was still a trend of functional decrease, especially at high Ca2+ concentration, it was much less pronounced relative to perfusion without theophylline (data not shown).

To date, the MR detection of H217O has used two approaches, i.e. direct detection via 17O MRS/I and indirect detection via 1H MRI. The indirect approach relies on 17O-induced changes in T or T2. It can be readily implemented on a clinical scanner at low field. However, the absolute quantification of H217O concentration can be complicated because of the sensitivity of the proton relaxation time to changes in the biochemical and physiological milieu in tissues (28). In addition, the relatively high radiofrequency power required by 1H spin-locking or 17O decoupling can also limit its application to patients. In comparison, direct 17O MRS/I has the advantage of being highly specificfor H217O, especially at high magnetic field with significantly improved signal-to-noise ratio. Potentially, the natural abundance H217O signal can be used as an internal reference. However, because of the high water content in blood, changes in blood volume can lead to changes in the natural abundance H217O signal. We observed a >15% decrease in the natural abundance H217O signal when the perfusion pressure was reduced from 100 cm water column to 40 cm (data not shown). Such changes are probably caused by changes in vascular volume in response to perfusion pressure. Therefore, care must be taken when using the natural abundance H217O signal as a reference.

The current study has several limitations. First, a simplified compartment model was used to estimate the oxygen consumption rate. Because of our inability to measure the 17O enrichment of the oxygen gas in the perfusate, current parameter estimation can only determine the metabolic rate of 17O-labeled oxygen rather than the total oxygen consumption. Although model-determined 17O2 consumption rates showed agreement with experimentally measured MVO2, the robustness of parameter estimation needs to be evaluated further. As the acquired 17O signal comprised signals from both the heart and the perfusate in the MR tube, further validation of the model can be accomplished by measuring H217O in the heart and perfusate separately, either by MRI or with the assistance of other methods, such as mass spectrometry. In addition, given the short T1 relaxation time (~5 ms) of 17O, a shorter TR (~20 ms) can be used to improve the signal-to-noise ratio and temporal resolution of data acquisition, which will lead to improved parameter estimation.

Second, the current system was not optimized for longer time durations. The need for cost-savings and for the maximization of detection sensitivity has rendered it a challenge to maintain normal cardiac function during the time course of data acquisition. The decrease in ventricular function at high Ca2+ concentration may have been caused by hypoxia because of increased oxygen extraction at high workload and the inability of the system to maintain adequate re-oxygenation of the perfusate. As a result, the model-fitted MV17O2 reflects an average index of oxygen consumption during the time course of 17O MRS acquisition. Nevertheless, these preliminary results demonstrate that 17O MRS on an isolated perfused heart can provide a valuable approach for the validation of in vivo 17O studies, as well as for the investigation of metabolic regulation in cardiac mitochondria under various pathophysiological conditions.

In conclusion, this study has demonstrated the feasibility and sensitivity of dynamic 17O MRS for the detection of the altered metabolic rate associated with changes in cardiac workload. In combination with kinetic modeling, this high-temporal-resolution MRS method allows the quantification of the mitochondrial respiration rate in beating hearts. When combined with 31P magnetization transfer for the quantification of ATP synthesis, 17O MRS provides a unique opportunity to evaluate the coupling between mitochondrial oxidation and phosphorylation in a nondestructive manner.

Acknowledgements

This work was supported by National Institutes of Health grants R01HL73315 and R01HL86935.

Abbreviations used

HCA

high calcium concentration group

HR

heart rate

LVDP

left ventricular developed pressure

MVO2

myocardial oxygen consumption rate

MV17O2

myocardial 17O2 consumption rate

NCA

normal calcium concentration group

PCr

phosphocreatine

PET

positron emission tomography

RPP

rate–pressure product

REFERENCES

  • 1.Ingwall JS, Weiss RG. Is the failing heart energy starved? On using chemical energy to support cardiac function. Circ. Res. 2004;95:135–145. doi: 10.1161/01.RES.0000137170.41939.d9. [DOI] [PubMed] [Google Scholar]
  • 2.Stanley WC, Recchia FA, Lopaschuk GD. Myocardial substrate metabolism in the normal and failing heart. Physiol. Rev. 2005;85:1093–1129. doi: 10.1152/physrev.00006.2004. [DOI] [PubMed] [Google Scholar]
  • 3.Neubauer S. The failing heart—an engine out of fuel. N. Engl. J. Med. 2007;356:1140–1151. doi: 10.1056/NEJMra063052. [DOI] [PubMed] [Google Scholar]
  • 4.Chatham JC, Forder JR. A 13C-NMR study of glucose oxidation in the intact functioning rat heart following diabetes-induced cardiomyopathy. J. Mol. Cell. Cardiol. 1993;25:1203–1213. doi: 10.1006/jmcc.1993.1133. [DOI] [PubMed] [Google Scholar]
  • 5.Stanley WC, Lopaschuk GD, McCormack JG. Regulation of energy substrate metabolism in the diabetic heart. Cardiovasc. Res. 1997;34:25–33. doi: 10.1016/s0008-6363(97)00047-3. [DOI] [PubMed] [Google Scholar]
  • 6.Wang P, Chatham JC. Onset of diabetes in Zucker diabetic fatty (ZDF) rats leads to improved recovery of function after ischemia in the isolated perfused heart. Am. J. Physiol. Endocrinol. Metab. 2004;286:E725–E736. doi: 10.1152/ajpendo.00295.2003. [DOI] [PubMed] [Google Scholar]
  • 7.Malloy CR, Sherry AD, Jeffrey FM. Evaluation of carbon flux and substrate selection through alternate pathways involving the citric acid cycle of the heart by 13C NMR spectroscopy. J. Biol. Chem. 1988;263:6964–6971. [PubMed] [Google Scholar]
  • 8.Malloy CR, Sherry AD, Jeffrey FM. Analysis of tricarboxylic acid cycle of the heart using 13C isotope isomers. Am. J. Physiol. 1990;259:H987–H995. doi: 10.1152/ajpheart.1990.259.3.H987. [DOI] [PubMed] [Google Scholar]
  • 9.Mateescu GD, LaManna JC, Lust DW, Mars L, Tseng J. Oxygen-17 magnetic resonance: in vivo determination of nascent mitochondrial water in animals breathing 17O-enriched air. Proc. Soc. Magn. Reson. Med. 1991;10:1031. [Google Scholar]
  • 10.Pekar J, Ligeti L, Ruttner Z, Lyon RC, Sinnwell TM, van GP, Fiat D, Moonen CT, McLaughlin AC. In vivo measurement of cerebral oxygen consumption and blood flow using 17O magnetic resonance imaging. Magn. Reson. Med. 1991;21:313–319. doi: 10.1002/mrm.1910210217. [DOI] [PubMed] [Google Scholar]
  • 11.Arai T, Mori K, Nakao S, Watanabe K, Kito K, Aoki M, Mori H, Morikawa S, Inubushi T. In vivo oxygen-17 nuclear magnetic resonance for the estimation of cerebral blood flow and oxygen consumption. Biochem. Biophys. Res. Commun. 1991;179:954–961. doi: 10.1016/0006-291x(91)91911-u. [DOI] [PubMed] [Google Scholar]
  • 12.Fiat D, Ligeti L, Lyon RC, Ruttner Z, Pekar J, Moonen CT, McLaughlin AC. In vivo 17O NMR study of rat brain during 17O2 inhalation. Magn. Reson. Med. 1992;24:370–374. doi: 10.1002/mrm.1910240218. [DOI] [PubMed] [Google Scholar]
  • 13.Zhu XH, Zhang Y, Tian RX, Lei H, Zhang N, Zhang X, Merkle H, Ugurbil K, Chen W. Development of (17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field. Proc. Natl. Acad. Sci. USA. 2002;99:13 194–13 199. doi: 10.1073/pnas.202471399. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Tailor DR, Baumgardner JE, Regatte RR, Leigh JS, Reddy R. Proton MRI of metabolically produced H217O using an efficient 17O2 delivery system. Neuroimage. 2004;22:611–618. doi: 10.1016/j.neuroimage.2004.02.024. [DOI] [PubMed] [Google Scholar]
  • 15.Mellon EA, Beesam RS, Baumgardner JE, Borthakur A, Witschey WR, Reddy R. Estimation of the regional cerebral metabolic rate of oxygen consumption with proton detected 17O MRI during precision 17O2 inhalation in swine. J. Neurosci. Methods. 2009;179:29–39. doi: 10.1016/j.jneumeth.2009.01.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Atkinson IC, Thulborn KR. Feasibility of mapping the tissue mass corrected bioscale of cerebral metabolic rate of oxygen consumption using 17-oxygen and 23-sodium MR imaging in a human brain at 9.4 T. Neuroimage. 2010;51:723–733. doi: 10.1016/j.neuroimage.2010.02.056. [DOI] [PubMed] [Google Scholar]
  • 17.Rogers WJ, Gupte PM, Piccione EA, Kramer CM, Vido DA, Reichek N. T2 imaging using O-17 for detection of viability in myocardial infarction. Proceedings of the 7th Annual Meeting ISMRM; Philadelphia, USA. 1999. p. 309. [Google Scholar]
  • 18.McCommis KS, He X, Abendschein DR, Gupte PM, Gropler RJ, Zheng J. New methods for the quantification of myocardial oxygen consumption with 17O MRI. Proceedings of the 17th Annual Meeting ISMRM; Honolulu, USA. 2009. p. 707. [Google Scholar]
  • 19.Zhu XH, Zhang Y, Chen W. In vivo 17O MRS imaging for assessing myocardial oxygen metabolism in rat heart at 9.4 T. Proceedings of the 18th Annual Meeting ISMRM; Stockholm, Sweden. 2010. p. 172. [Google Scholar]
  • 20.McCommis KS, He X, Abendschein DR, Gupte PM, Gropler RJ, Zheng J. Cardiac 17O MRI: toward direct quantification of myocardial oxygen consumption. Magn. Reson. Med. 2010;63:1442–1447. doi: 10.1002/mrm.22382. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Neely JR, Liebermeister H, Battersby EJ, Morgan HE. Effect of pressure development on oxygen consumption by isolated rat heart. Am. J. Physiol. 1967;212:804–814. doi: 10.1152/ajplegacy.1967.212.4.804. [DOI] [PubMed] [Google Scholar]
  • 22.Iida H, Rhodes CG, Araujo LI, Yamamoto Y, de Silva R, Maseri A, Jones T. Noninvasive quantification of regional myocardial metabolic rate for oxygen by use of 15O2 inhalation and positron emission tomography. Theory, error analysis, and application in humans. Circulation. 1996;94:792–807. doi: 10.1161/01.cir.94.4.792. [DOI] [PubMed] [Google Scholar]
  • 23.Peterson LR, Gropler RJ. Radionuclide imaging of myocardial metabolism. Circ. Cardiovasc. Imaging. 2010;3:211–222. doi: 10.1161/CIRCIMAGING.109.860593. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Yamamoto Y, de Silva R, Rhodes CG, Iida H, Lammertsma AA, Jones T, Maseri A. Noninvasive quantification of regional myocardial metabolic rate of oxygen by 15O2 inhalation and positron emission tomography. Experimental validation. Circulation. 1996;94:808–816. doi: 10.1161/01.cir.94.4.808. [DOI] [PubMed] [Google Scholar]
  • 25.Lewandowski ED. Nuclear magnetic resonance evaluation of metabolic and respiratory support of work load in intact rabbit hearts. Circ. Res. 1992;70:576–582. doi: 10.1161/01.res.70.3.576. [DOI] [PubMed] [Google Scholar]
  • 26.Lee HB, Blaufox MD. Blood volume in the rat. J. Nucl. Med. 1985;26:72–76. [PubMed] [Google Scholar]
  • 27.Belardinelli L, Linden J, Berne RM. The cardiac effects of adenosine. Prog. Cardiovasc. Dis. 1989;32:73–97. doi: 10.1016/0033-0620(89)90015-7. [DOI] [PubMed] [Google Scholar]
  • 28.Zhu XH, Zhang N, Zhang Y, Zhang X, Ugurbil K, Chen W. In vivo 17O NMR approaches for brain study at high field. NMR Biomed. 2005;18:83–103. doi: 10.1002/nbm.930. [DOI] [PubMed] [Google Scholar]

RESOURCES