Table 4. Agreement of duplicate probing depth measurements for intra-examiner A, intra-examiner B and inter-examiner A-B for facial and lingual surfaces (%).

Variation (mm) Facial
A B A-B
±0.0 55.7 57.9 49.8
±0.5 86.9 94.5 85.9
±1.0 98.8 100.0 98.5
±1.5 99.5 100.0 99.8
±2.0 100.0 100.0 100.0
Lingual
±0.0 55.5 57.9 47.0
±0.5 84.3 90.6 82.4
±1.0 99.7 99.8 98.5
±1.5 100.0 100.0 99.8
±2.0 100.0 100.0 100.0