Table 1.

Processing parameters for siRNA-nanofiber scaffolds

Samples Volume ratioa Equivalent
molar ratiob
Electrospinning parameters
Random fibers Aligned fibersd
siCOL1A1/MPG,
siNEG/MPG
1/2 1/15 +12/-4 kV
1.5 mL/h
12 cmc
5 × 5 cm2
-
1/3 1/20 -
1/4 1/30 2500 rpme
siCOL1A1/CADY,
siNEG/CADY
1/2 1/15 -
1/3 1/20 -
1/4 1/30 2500 rpme
siCOL1A1/TKO,
siNEG/TKO
1/2 1/15 2500 rpme
PCLEEP (plain fibers) - -
a

Volume ratios of 1/2 (15µL/30µL), 1/3 (15µL/45µL) and 1/4 (15µL/60µL)

b

Conversion of volume ratios to molar ratios

c

Distance from needle tip to collector surface

d

All parameters were the same as random fibers except for the inclusion of a grounded rotating target

e

A grounded rotating target