Skip to main content
. 2012 Oct 30;5(1):83–89. doi: 10.3892/ol.2012.1004

Table I.

Details of MRI techniques.

Technique TR (msec) TE (msec) FA BW (Hz) Profile order TFE Voxel size (mm) Fat supression Diffusion b-factor No. of signal averages Scan time Dynamic phase Slice orientation
Diffusion-weighted image: single shot EPI 4067 82 90 22.2 - - 2.23 (0.98) × 2.80 (0.98) × 3.5 SPAIR 0, 800 6 1 min 55 sec - Transverse
Dynamic study: 3D FFE 11.0 5.6 20 992.1 - - 1.12 (0.49) × 1.12 (0.49) × 10.0 (5.0) Proset (1:3:3:1) - 1 30.2 sec/phase 6 (pre,1,1.5, 2,4,6 min) Coronal
High resolution image: 3D TFE 3.5 1.74 10 1183.7 Low-high radial 40 1.33 (0.80) × 1.33 (0.80) ×1.70 (0.85) SPAIR - 3 2 min 9 sec - Sagittal

MRI, magnetic resonance imaging; BW, bandwidth; EPI, echo planar imaging; FA, fractional anisotorpy; FFE, fast field echo; SPAIR, spectral adiabatic inversion recovery; TE, echo time; TFE, turbo field echo; TR, repetition time.